8.1

Indications on Display

Indication
on Display
FLF
FLF
FLO
FLO
Fue
Fue
Hop
Hop
HOS
HOS
LEA
LEA
>
>
>
LHE
LHE
LHL
LHL
POL
POL
SEC
SEC
SEO
SEO
UPC
UPC
16
Cause
>
Flow sensor fault
>
Water supply turned off or inadequate supply
to machine
>
Detergent tank empty
>
Pressure regulation on the safety control
block or VarioPress-lance
volume
>
Machine scaled
Fuel shortage
>
>
Motor overheated
>
Machine overheated
>
Leakage or inadmissible operating condition
by short-time operation
Spray gun leaking
>
High pressure hose, coupling or line system
leaking
>
Detergent tank empty
Water inlet fi lter dirty
High-pressure pump drawing in air
>
Flame sensor sooted
>
Ignition or fuel system failure
>
Burner failure
>
Pump oil low
>
Temperature sensor damaged
>
Temperature sensor damaged
>
Microprocessor failure
1)
set to low water
Repair Spray gun
Clean fi lter (see chapter 7.2.1)
Repair leaks
Remedy
Contact Nilfi sk-Alto Service
Cold water operation possible
Required volume fl ow and pressure see
chapter 9.3 Technical Data
Fill detergent tank or set detergent me-
tering to „OFF"
Turn the twist grip on safety control block
1)
or VarioPress-lance
to higher water/
pressure volume (see chapter 4.4)
Contact Nilfi sk-Alto Service
Fill fuel tank
Cold water operation possible
Turn main switch in position „OFF", let
machine cool down
Remove extension cord, if being used.
Possible phase failure; have electrical
connections checked
Contact Nilfi sk-Alto Service
After three times of short-time ope ration
the machine switches off. To reset: Turn
main switch to position "OFF", then start
again. Keep trigger squeezed for longer
than 3 seconds. If a leak occurs in the
hose and gun and causes the machine
to start and stop briefl y 3 times, then the
machine will switch off.
Replace high-pressure hose, retighten
screw fi ttings
Fill detergent tank or set detergent me-
tering to „OFF"
Clean flame sensor (see chapter
7.2.6).
Contact Nilfi sk-Alto Service
Cold water operation possible
Contact Nilfi sk-Alto Service
Cold water operation possible
Fill to proper level (see chapter 7.2.3)
Contact Nilfi sk-Alto Service
Cold water operation possible
Contact Nilfi sk-Alto Service
Cold water operation possible
Contact Nilfi sk-Alto Service
1)