Channel Number
This sets a unique address number into your transmitter. Later, when you set up
your measurement software you will again set channel numbers to receive
readings from the corresponding unit(s). Each unit must be set for a different
channel number for your system to operate correctly.
If you will be using more than one receiver unit in your area it
is important to set the transmitter address numbers to be a
corresponding number in your TC-Central software.
Example Rate
For the first receiver: Set the channels on your transmitters to
101, 102, 103, 104, etc. Then set the channels in your TC-
Central user software to match.
For the second receiver: Set the channels on your transmitters
to 201, 202, 203, 204, etc.
Then set the channels in your TC-Central user software to
match.
This numbering scheme can be expanded to match the
number of receivers you are using.
Sample Rate
This will program your End Device to transmit 1 data reading to your receiver at
a specified time interval. Available settings are 2, 3, 5, 15, 30, 45, 60, 75 or 90
seconds
The sample rate you set will have the most direct effect on the
life of the battery in your End Device. It is recommended that
you set the longest sample time that your application can live
with to extend time between battery replacement. See
Section 5.3 for more information on battery
End Device Operation
NOT :
NOT :
5
5-2