BREAKPOINT
Press NET to show the current break point setting. Press ON/ZERO to select
b=
break point setting (1 through 99). Press the NET key to save setting.
MOTION RANGE
Press the NET key to show the current motion range in divisions. Then press the
UnS=
ON/ZERO key to select the number of digits to change before motion: 0 through
9. Press the NET key to save.
SAMPLE RATE
Press the NET key to show the current sample rate setting. Values of 1 through
Sr=
12 are valid for the sample rate. Press the ON/ZERO key to select 1 through 9
samples per second, then press the NET key to save. If a sample rate of 10
through 12 is desired, first press the ON/ZERO key to select 0 through 2, then
press the TARE key to advance to the next digit location and press the ON/ZERO
key to select 10 through 12 samples per second. Press the NET key to save.
AUTOMATIC SHUTOFF
Press the NET key to show the current setting. Then press the ON/ZERO key to
ASh=
disable the feature or to select the number of minutes of inactivity before turning off
the scale. 0= disable, 1 to 9= minutes of inactivity before shutoff. Press the NET
key to save it.
SLEEP MODE
Press the NET key to show the current setting. Then press the ON/ZERO key to
SLP=
disable the feature or to select the number of minutes at zero before going to sleep.
0=disable, 1 to 9=minutes of inactivity before sleeping. Press the NET key to save
it.
PUSH BUTTON TARE
Press the NET key to show the current setting. Then press the ON/ZERO key to
Pbt=
toggle between yes and no. YES=enable, no=disable. Press the NET key to save.
The display will display the software revision number and then the gross weight. The setup and
calibration process has been completed and the scale is ready to weigh. Place the test weight back
on the scale to verify calibration.