Cardinal Detecto 6732 Operation Manual

Neonatal scale

Advertisement

Cardinal
®
Neonatal Scale
6732, 6733,
6735, and 6736
Operation Manual
Cardinal Scale Mfg. Co.
P.O. Box 151 Webb City, MO 64870
8525-M039-O1 Rev E
Ph: 417-673-4631 / Fax: 417-673-5001
Printed in USA
10/03
web site - www.detectoscale,com

Advertisement

Table of Contents
loading

Summary of Contents for Cardinal Detecto 6732

  • Page 1 Cardinal ® Neonatal Scale 6732, 6733, 6735, and 6736 Operation Manual Cardinal Scale Mfg. Co. P.O. Box 151 Webb City, MO 64870 8525-M039-O1 Rev E Ph: 417-673-4631 / Fax: 417-673-5001 Printed in USA 10/03 web site - www.detectoscale,com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction ......1 Features And Specifications ..1 Components And Controls ..2 Installation ........ 3 Power Supply ....... 4 Start-up ........ 4 Keyboard Functions ....4 Operation ......... 5 Operating Instructions ....6 Care And Maintenance ..... 6 Error And Fail Messages ..
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasing Detecto Model 6700 Series Neonatal Scale. This instrument has been designed and manufactured in the USA. The Model 6700 Series Neonatal Scale is a solid-state digital scale designed for weighing newborn infants. The Neonatal Scale features a lb/kg key for metric conversion of the infant’s weight.
  • Page 4: Components And Controls

    COMPONENTS AND CONTROLS...
  • Page 5: Installation

    INSTALLATION 1. Unpack scale and infant tray and note any discrepancies in its condition. Keep carton and packing for return shipment of instrument if necessary. 2. Place scale on a stable, vibration-free location away from direct sunlight and away from any rapidly moving air source. Make certain power cord is stored out of the way of normal traffic.
  • Page 6: Power Supply

    POWER SUPPLY 1. Plug power cord into a fully grounded, 3-pronged wall receptacle that supplies 115 VAC power. If an extension cord must be used, it should be a 3- wire, fully grounded type. 2. If a 2-pronged wall receptacle is encountered, it is the responsibility of the customer to contact a qualified electrician to replace the 2-pronged receptacle with a properly grounded 3-pronged wall receptacle or have a grounding adapter properly installed in the 2-pronged receptacle.
  • Page 7: Operation

    OPERATION...
  • Page 8: Operating Instructions

    OPERATING INSTRUCTIONS Place blanket or covering on tray. Press TARE/ZERO key. Place infant on scale. Read weight when display stops flashing. If infant movement causes display to continuously flash, press CLEAR WT. key to lock weight on display. Remove infant and blanket covering from tray. Press CLEAR WT.
  • Page 9: Error And Fail Messages

    ERROR AND FAIL MESSAGES FAIL A This message indicates a bad electrical component requiring technical service. UnStb This message occurs when the infant platform is persistently unstable upon turning on scale. This condition occurs when turning on scale without the infant tray on the scale.
  • Page 10: Spare Parts Identification

    SPARE PARTS IDENTIFICATION Item No. Part No. Description 2950-C014-4A LOAD CELL & CONNECTOR ASSEMBLY (SP-50L) 427XR1346 BABY TRAY 427R1348 RULER FOR BABY SCALE 442R137 KEYPAD: 6735 BABY SCALE 6540-1011 LEVELER SCREW, 1/4-20x1" LONG, S.S. 6610-4019 FUSE 1/4 ASB 3AG-1/4 ASB 6610-4046 FUSE HOLDER PANEL MOUNT KNOB TYPE 8535-D200-0A...