BATTERY INSTALLATION, Cont. Battery Pack Battery Battery Compartment Cover Step 3 Replace the battery compartment cover and retaining screws. NOTE! If the HSDC scale fails to operate after battery replacement check to make certain that each of the six cells has been installed correctly. One cell installed backward will prevent the scale from operating.
SCALE OPERATION, Cont Scale Component Identification Press to turn the scale off. The auto-shutoff feature will turn the scale off automatically after a preselected time of inactivity (no motion). Press to place the scale in the gross weight display mode (net indicator off). GROSS Press to enter a new tare weight value equal to the current scale weight.
TARE WEIGHT ENTRY, Cont. Pressing the TARE key will cause the currently displayed gross weight to be stored as the new tare weight and cause the scale to enter the net weight display mode. The net weight display mode is indicated by turning on the net annunciator.
CALIBRATION Your HSDC hanging scale has been calibrated prior to shipment and should not require re- calibration before it is placed in service. A regular check of the instrument’s calibration should be made to ensure that its weighing accuracy is maintained. To check the calibration of your HSDC hanging scale, you must have a calibrated test weight or weights equal to the scale’s capacity.
CALIBRATION, Cont. DECIMAL POINT Press the NET key to show the current setting. Then press the ON/ZERO key to dPP= select the desired value: 0=XXXX 1=XXX.X 2=XX.XX 3=X.XXX Press the NET key to save. CAPACITY Press the NET key to show the current capacity setting. Then press the ON/ZERO CAP= key to advance the flashing digit from 0 through 9 (200.0).
Page 10
CALIBRATION, Cont BREAKPOINT Press NET to show the current break point setting. Press ON/ZERO to select break point setting (1 through 99). Press the NET key to save setting. MOTION RANGE Press the NET key to show the current motion range in divisions. Then press the UnS= ON/ZERO key to select the number of digits to change before motion: 0 through 9.
Page 11
CALIBRATION, Cont Calibration Switch Front of Instrument Underside of Scale Table 1 -- Setup Settings for HSDC Models Model HSDC int= dPP= CAP= 5000 2000 9995 4000 2000 9995 4000 2000 Unt= trA= trL= trL= YES is for Canadian PUO= FLt= UnS= Skip if FLt= 1 or 2...
SETUP REVIEW The HSDC allows several operational parameters to be reviewed and changed as necessary without having to break the calibration seal and enter the setup and calibration mode. The setup review allows changes to be made to the power up zero setting, the automatic shutoff and sleep mode delay times, push button tare.
C. Scale in net mode. Press the GROSS key. If you are unable to resolve the difficulty, contact the Cardinal Scale representive from whom you purchased the scale. He will be able to provide you with information concerning the return and repair of your scale.