Once the unit is located in the final installed location and the rear of the unit is level, proceed to
level the front.
NOTE: When leveling the front of the unit, the front should be ½ bubble higher than the back.
1. Use a flat blade screwdriver to rotate the front roller leveling screws in the appropriate direction
to level the unit side to side. (Fig. 59 & 60)
2. Use a level and check to make sure the rollers are set so the unit is level side to side and ½
bubble higher in front.
VIEW OF ROLLER WITH NO HINGE
Fig. 59
LOWER
RAISE
Electrical Requirements
A 115 V, 60 Hz, 15 TO 20 Amp fused circuit utilizing a 3-wire grounding receptacle meeting all
national and local electrical codes is required. It is recommended that a separate circuit serving
only this appliance be provided.
MID-LINE DESIGN
Leveling
Screw
!
WARNING
To avoid the risk of electrical shock,
property damage, personal injury or death:
The power cord must be plugged into a 3-prong grounding-type
wall receptacle, grounded in accordance with the National
Electrical Code, ANSI/NFPA 70 - latest edition, and local codes
and ordinances.
It is the personal responsibility of the consumer to have a proper
3-prong wall receptacle installed by a qualified electrician.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE
POWER CORD GROUNDING PRONG.
Do not remove any grounding wires
from individual components while
servicing, unless the component is
to be removed and replaced. It is
extremely important to replace all
grounding wires when components
are replaced.
50
VIEW OF ROLLER WITH HINGE IN PLACE
Fig. 60
Leveling
Screw
Grounding Type
Receptacle
16 thru 22 cu. ft. Top-Mount
3-Prong
Grounding Plug