Converting the Pressure Sensing Tube
The Top Vent pressure sensing tube must be removed and
replaced with supplied Rear Vent pressure sensing tube.
Figure 6...Factory.installed.Top.Vent.Pressure.Sensing.Tube
Figure 6a...Supplied.Rear.Vent.Pressure.Sensing.Tube
Page 12

Installation

1. Remove six screws from the firebox ceiling baffle to access
pressure sensing tube from the inside of the firebox, as shown in
figure 6b.
2. Remove Top Vent pressure sensing tube by loosening the
compression nut with a ½" wrench.
Figure 6b...Removal.of.Top.Vent.air.baffle.and.pressure.sensing.tube.
.(cutaway.view)
3. Position the supplied Rear Vent pressure sensing tube as
shown in Figure 6c, position the tube in the center of the 5
inch pipe. Hand tighten the compression nut and tighten half
a turn with a wrench. DO NOT OVERTIGHTEN.
4. Re-install the firebox ceiling baffle.
Figure 6c...Installation.of.Rear.Vent.air.baffle.and.pressure.sensing.
tube..(cutaway.view)
Top of Firebox
Pressure Tube
Firebox ceiling
with baffle
removed
Top of Firebox
XG0777 - 100113.1