Section 5: Installing the gas line

Gas Pressure
Optimum appliance performance requires proper inlet pressures.
Gas line sizing requirements will be determined in ANSI Z221.3
National Fuel Gas Code in the USA and CAN/CGA B149 in Canada.
Pressure requirements:
Pressure Requirements
Gas Pressure
Maximum Inlet Pressure 14" WC (1/2 psi) 14" WC (1/2 psi)
Minimum Inlet Pressure
(with fireplace on)
Manifold Pressure
The manifold outlet pressure is set from the factory to the
appropriate pressure but should be verified.
To check pressures, gas valves have a provision to remove a
1/8" MPT plug and to be fitted with a hose barb.
Montigo requires a service shut off valve be located in an
accessible location to isolate the appliance.
Figure 14...Pressure.Testing
MANIFOLD PRESSURE
Figure 14a...HSI.Valve
XG0777 - 100113.1
Installation
Natural Gas
Propane
5.5" W.C.
11" W.C.
3.5" W.C.
10" W.C.
+/- 2
+/- 0.3
MANIFOLD
RP620 Power Vent Indoor Gas Fireplace
Only install gas shut-off valves approved for use by the state,
province, or other governing body in which the fireplace is
being installed.
GAS CONNECTION
See Figure 15 below for location of gas line access.
Flexible gas connectors must not exceed 3 feet in length, unless
allowable within local regulations.
Connect incoming gas line to the 1/2" MPT gas inlet.
Purge all air out of gas line before connecting.
Check appliance connection, valve and valve train under
normal operating pressure with a commercially available leak
check solution.
DO NOT USE A FLAME OF ANY KIND TO TEST FOR LEAKS.
Gas Inlet
Control Cable
Figure 15. Identifying.the.Gas.Inlet
psi. This will damage the gas control valve.
Lights
Page 19