Section 3-1: Converting to Rear Vent
RP-Series units are shipped for Top Vent installations. Follow the
instructions to convert unit for Rear Vent installation.
Section 3-1-1: Converting the Flue
1. Remove the Rear flue cover with gasket (5" and 8") on
the flue outlet, as shown in Figure 5. ENSURE YOU DO
NOT DAMAGE THE FIBER GASKETS.
2. Remove the Top flue collar (5" and 8") on the flue outlet,
as shown in Figure 5. ENSURE YOU DO NOT DAMAGE
THE FIBER GASKETS.
Note: Read instructions for converting pressure sensing tube, page 12.
You may find it easier to convert the pressure sensing tube at this time .
5" Flue Cover Plate
(with gasket)
8" Flue Cover Plate
(with gasket)
Figure 5...Flue.cover.and.collar.removal,.Top.Vented.fireplace
XG0777 - 100113.1

Installation

5" Inner Flue Collar
(with gasket)
Figure 5a...Flue.cover.and.collar.installation,.Rear.Vented.fireplace
8" Outer Flue Collar
(with gasket)
RP620 Power Vent Indoor Gas Fireplace
3. Install the removed Rear flue cover (5" and 8") to the Top
Vent outlet. Fasten the cover with included hardware, as
shown in Figure 5a.
4. Install the collars (5" and 8") to the rear vent outlet using
the included hardware, as shown in Figure 5a.
8" Outer Flue Collar
(with gasket)
5" Inner Flue Collar
(with gasket)
5. Proceed to Section 3-1-2: Converting Pressure Sensing
Tube and Air Baffle.
8" Flue Cover Plate
(with gasket)
5" Flue Cover Plate
(with gasket)