Section 4: Wiring

Installing the Fireplace Control Box
Install the Fireplace Control Box in an accessible location. The
location should be where maintenance, adjustments and service
may be made easily.
Installation of Electrical Supply
The RP620* is supplied with an external electrical control box pre-
wired by the factory. The control box is connected to the fireplace
with a 30 foot long 6-conductor cable that will communicate with
the fireplace. Extension cables are available through your Montigo
Dealer only.
A 20ft low voltage black / white cable is provided for connection
to a single pole on/off switch. The length of this cable can be
extended up to a length of 100ft using a cable of equal or greater
capacity. This system operates on 24VAC. Do not connect this
switch circuit to an external power source.
Optional remote control available through your Montigo Dealer.
Do not use third party remote controls without the approval from
Montigo.
Installations in Canada must be electrically grounded in
accordance with CSA C22.1 Canadian Electrical Code Part 1
and/or Local Codes.
Installations in the USA must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70.
Power
Vent Fuse
(5A)
LED
Power
Indicator
Control
Panel Fuse
(5A)
Figure 10...Control.box.Diagram.
XG0777 - 100113.1

Installation

Prepurge
Power Vent
Post Purge
Timer (1 min.)
Timer (3 min.)
Connector
RP620 Power Vent Indoor Gas Fireplace
LED Indicator
Wall Switch
Control
115V
cable
Power Supply
Fuse
Outlet
115V
Left-side View
Figure 11. Control Box
Note: If any of the original wire supplied with the appliance is
replaced, it must be with the same or it's equivalent.
Conduit & Wiring clearances
Connect the power vent harness as outlined in the previous section.
Ensure that the proper clearances are maintained for the wiring and
conduit. When installing the wiring it must never run above the vent
run and it must be at least 1" clear of all venting.
Wire
1" Clearance
Figure 12. Conduit and Wiring
Power Vent
Speed Control
Power Vent Harness
Right-side View