3Section 3: Mounting And Connection; Overview; General Considerations - Emerson Smart Wireless Gateway 1410 Reference Manual

Emerson smart wireless gateway 1410
Hide thumbs Also See for Smart Wireless Gateway 1410:
Table of Contents

Advertisement

Reference Manual
00809-0200-4410, Rev BA
Section 3
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18
Remote antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 20
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22
Explosions could result in death or serious injury:
Electrostatic discharge can damage electronics:
Electrical shock could cause death or serious injury. If the device is installed in a
high-voltage environment and a fault condition or installation error occurs, high voltage
may be present on transmitter leads and terminals.
Failure to follow these installation guidelines could result in death or serious injury:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
conditions: This device may not cause harmful interference, this device must accept any
interference received, including interference that may cause undesired operation.
This device must be installed to ensure a minimum antenna separation distance of 20 cm
from all persons.
3.1

Overview

This section describes how to properly mount the Gateway and make electrical connections,
including electrical wiring, grounding, and host system connections. This section also describes
how to mount the optional remote antenna.
3.1.1

General considerations

The unit itself is not designed for outdoor mounting without a suitable enclosure. The Gateway
should be mounted in an approved electrical enclosure or building.
The Gateway should be mounted in a location that allows convenient access to the host system
network (process control network) as well as the wireless field device network and protects the
Gateway from moisture and contamination.
Mounting and connection
Mounting and connection
Verify that the operating atmosphere of the device is consistent with the appropriate
hazardous locations certifications.
Use proper personal grounding before handling electronics or making contact with
leads and terminals
Use extreme caution when making contact with the leads and terminals.
Make sure only qualified personnel perform the installation.
Section 3: Mounting and connection
February 2014
17