Routes; Serial; Sntp - Multitech MultiConnect rCell MTR-H5 Developer's Manual

Multiconnect rcell api cellular router
Hide thumbs Also See for MultiConnect rCell MTR-H5:
Table of Contents

Advertisement

Element
accountKey
allowConfigurationUpgrade
allowFirmwareUpgrade
enabled
gpsDataInterval
queryServerInterval
serverName
serverPort
sslEnabled
syncWithDialOnDemand
4.3.21

routes

Description: list of static routes : ARRAY
Element
Type
Description
gateway
STRING
default gateway of route
ip
STRING
ip address of route
mask
UINT
network mask of route (0-32)
name
STRING
name of route
4.3.22

serial

Description: settings for serial port : OBJECT
Element
Type
Description
baudRate
UINT
(default:115200)
dataBits
UINT
(default:8)
flowControl
STRING
RTS-CTS or NONE (default:NONE)
modbus
BOOL
enable or disable modbus (default:false)
parity
STRING
ODD, EVEN or NONE (default:NONE)
stopBits
UINT
(default:1)
type
STRING
if device support flexible serial port: RS-232, RS-422, or RS-485 (default:RS-232)
4.3.23

sntp

Description: settings for clock synchronization between computer systems : OBJECT
Element
Type
enabled
BOOL
pollingTime
UINT
server
STRING
timeZone
STRING
24
Type
Description
STRING
account key registered to user by device management platform
BOOL
allow configuration upgrades to be managed through device management plat-
form (default:true)
BOOL
allow firmware upgrades to be managed through device management platform
(default:true)
BOOL
enable the device to be managed by a remote management platform (default:false)
UINT
set the gps push interval in seconds (default:43200)
UINT
set the check-in interval in seconds (default:43200)
STRING
remote management platform's url or IP address (default:ds.multitech.com)
UINT
remote management platform's IP port (default:5798)
BOOL
enable traffic encryption (default:true)
BOOL
only allow the device to contact the remote management platform when the
cellular link is already up (default:false)
Description
enable or disable SNTP client (default:false)
frequency in minutes to poll current time (default:120) [0-1440]
ip address or domian name of server
zoneinfo file path to use as timezone : (default:UTC)
Multi-Tech Systems, Inc. MultiConnect
4
COMMANDS AND COLLECTIONS
R
rCell API Developer Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MultiConnect rCell MTR-H5 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Multiconnect rcell mtr-h6Multiconnect rcell mtr-g3Multiconnect rcell mtr-ev3Multiconnect rcell mtr-c2Multiconnect rcell mtr-h6Multiconnect rcell mtr-g3 ... Show all

Table of Contents