PROBLEM
Oil in fryer vessel boils over
Basket-Lift mechanism won't operate
Basket-Lift motor runs, but basket
doesn't move
Basket-Lift basket goes down, but won't
go up.
Basket-Lift buzzer won't shut off

ORDERING PARTS

Parts may be ordered by calling 1-800-KEATING or your local Keating service company. You may also order on-line
at Keating's part store, www.keatingofchicago.com
Refer to the Keating Gas Fryer Limited Warranty for complete service and ordering information.
The model/serial plate is attached to the inside of the front door. The serial and model numbers are necessary
when ordering.
NOTE: On Drop-In fryers, the model/serial plate is attached to the top of the control panel.

WARNING AND OPERATING PLATES

All warning and operating plates on the Instant Recovery® Gas Fryer should be in place at all times.
If plates are damaged or lost, replace them immediately.
PROBABLE CAUSE
a. Baskets overfi lled.
b. Fryer vessel overfi lled with oil.
c. Oil is breaking down and foaming.
d. Water in cold zone.
a. Connections are loose or timer faulty.
b. Motor limit switch is faulty.
c. Lift motor is faulty (14" model).
d. Actuator is faulty (18" and above
models).
e. Control circuit fuse has blown.
f. Relay is faulty (18" and above models).
a. Cam is slipping on motor shaft (14"
model).
a. Basket-Lift motor limit switch is
misaligned (14" model).
a. Buzzer limit switch is misaligned
(14" model).
GAS FRYER - SERIES PRE-2000
SOLUTION
a. Don't over fi ll baskets.
b. Fill fryer up to "Fill Level" line as oil
expands when heated.
c. Replace oil.
d. Stir oil with a paddle until water boils
off. Filter oil. If water remains, let oil
cool and drain a quart of it.
a. Tighten connections. Replace timer if
faulty.
b. Replace limit switch (14" model).
Replace actuator (18" and above
models).
c. Replace motor. Specify left or right side
motor when ordering.
d. Replace actuator.
e. Replace fuse (use type SC-5 in 14"
model and type SC-3 in 18" and above
models).
f. Replace relay.
a. Tighten cam onto fl at on motor shaft.
a. Align limit switch.
a. Align limit switch.