Ordering Parts - Keating Of Chicago SERIES 2009 Manual

Gas fryer
Hide thumbs Also See for SERIES 2009:
Table of Contents

Advertisement

PROBLEM
Flames come out front of fryer
Fryer has poor recovery or runs cold
Basket-Lift mechanism will not operate
Fryer is making a lot of noise

ORDERING PARTS

Parts may be ordered by calling 1-800-KEATING or your local Keating service company. We recommend using
genuine Keating Replacement Parts - engineered and manufactured specifi cally to meet exact specifi cations and
requirements for Keating equipment.
Refer to the Keating Gas Fryer Limited Warranty for complete service and ordering information.
The model/serial plate is attached to the inside of the front door. The serial and model numbers are necessary
when ordering.
NOTE: On Drop-In fryers, the model/serial plate is attached to the top of the control panel.
WARNING AND OPERATING PLATES
All warning and operating plates on the Instant Recovery® Gas Fryer should be in place at all times.
If plates are damaged or lost, replace them immediately.
|
18
keatingofchicago.com
PROBABLE CAUSE
a. Exhaust problems.
b. Radiants have slipped forward.
c. Flue blockage.
a. Baskets overfi lled.
b. Fryer vessel overfi lled with oil.
c. Carbon coating on heat transfer tubes.
d. Radiant collapsed or out of position.
e. Faulty or erratic thermostat.
f. Low gas supply or pressure.
g. Thermostat bulb improperly placed.
a. Connections are loose or timer faulty.
b. Breaker has tripped.
c. Basket-lift relay is faulty.
d. Actuator is defective.
a. Misadjusted air shutters on the
burners.
SOLUTION
a. Install defl ector to block down draft.
Install or adjust fl ue restrictors. If
problem persists, contact your HVAC
representative.
b. Reposition radiants.
c. Turn fryer and manual gas valve off. Let
fl ue cool and remove foreign objects.
a. Don't over fi ll baskets.
b. Fill fryer up to "Fill Level" line or "Max
Level" line as oil expands when
heated.
c. Boil-out fryer. See pages 11-13,
Cleaning and boil-out.
d. Reposition or replace radiants.
e. Replace thermostat.
f. Verify if size of incoming gas line to
fryer and manifold gas pressure are
adequate.
g. Adjust bulb position. See page 13,
thermostat bulb positioning.
a. Tighten connections. Replace timer if
faulty.
b. Reset breaker located on power box in
rear of fryer. Citcuit breakers on newer
units can be found under the control
panel.
c. Replace relay.
d. Replace actuator if 24VDC is present.
a. Loosen screw that holds the air shutter
on the burner. Move air shutter so the
screw is in the middle of the slot on
the shutter. Make all the shutters the
same.

Advertisement

Table of Contents
loading