PROBLEM
Oil in fryer vessel boils over
Contactor chatters
Basket-Lift mechanism will not operate
Basket-Lift motor runs, but basket
doesn't move
Basket-Lift basket goes down but won't
go up
Basket-Lift buzzer won't shut off.

ORDERING PARTS

Parts may be ordered by calling 1-800-KEATING or your local Keating service company. We recommend using
genuine Keating Replacement Parts - engineered and manufactured specifi cally to meet exact specifi cations and
requirements for Keating equipment.
Refer to the Keating Electric Fryer Limited Warranty for complete service and ordering information.
The model/serial plate is attached to the inside of the front door. The serial and model numbers are necessary
when ordering.
NOTE: On Drop-In fryers, the model/serial plate is attached to the top of the control panel.

WARNING AND OPERATING PLATES

All warning and operating plates on the Instant Recovery® Electric Fryer should be in place at all times.
If plates are damaged or lost, replace them immediately.
|
12
keatingofchicago.com
PROBABLE CAUSE
a. Baskets are overfi lled.
b. Fryer vessel overfi lled with oil.
c. Oil is breaking down and foaming.
d. Water in cold zone.
a. Voltage is low to fryer.
b. Contactor coil faulty.
c. Connections are loose.
d. Thermostat contacts do not close
properly.
a. Connections are loose or timer is
faulty.
b. Motor limit switch is faulty.
c. Lift motor is faulty (10x11 and
14 TS BL models).
d. Actuator is faulty (18 TS BL Model
and above).
e. Control circuit fuse has blown.
f. Relay is faulty (18 TS BL Model and
above).
a. Cam is slipping on motor shaft
faulty. (10x11 and 14 TS BL models).
a. Basket-Lift motor limit switch is
misaligned (10x11 and 15 TS BL
Models).
a. Buzzer limit switch is misaligned
(10x11 and 14 TS BL models).
SOLUTION
a. Don't overfi ll baskets.
b. Fill fryer up to "Fill Level" line as oil
expands when heated.
c. Replace oil.
d. Stir oil with a paddle until water boils
off. Filter oil. If water remains, let oil
cool and drain a quart of it.
a. Contact your electrician or the local
power company and have the incoming
power checked.
b. Replace contactor.
c. Tighten connections.
d. Replace thermostat.
a. Tighten connections. Replace timer if it
will not operate.
b. Replace Motor limit switch (10x11 and
14 TS BL). Replace actuator (18 TS BL
Model and above.)
c. Replace motor. Specify left or right side
motor when ordering.
d. Replace fuse (use type SC-5 in 10x11
BL Models and type SC-3 in 18 TS
Model and above.
e. Replace relay.
a. Tighten cam onto motor shaft.
a. Align limit switch.
a. Align limit switch.