  • Page 2 PURCHASER SHOULD POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY CON- SULTING THE LOCAL GAS SUPPLIER. WARNING Burns Shock Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
  • Page 3: Table Of Contents

    GAS FRYER - SERIES 2000  TABLE OF CONTENTS Electronic Timers ............7 - 8 Important Safety Instructions ..........i Oil Breakdown ............8 - 9 INTRODUCTION .............. 1 INSTALLATION Draining ................9 Damage During Shipment ..........1 Cleaning and Boil-Out ..........9 - 10 Safety Precautions ............
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS The Keating Gas Fryer must be installed in an area providing adequate air supply and ventilation. Do not obstruct the fl ow of combustion and ventilation air. Proper ventilation is one of the important consider- THIS SYMBOL WARNS YOU THAT SERIOUS BURNS ations for effi...
  • Page 5: Leveling

    GAS FRYER - SERIES 2000 LEVELING The fryer will operate at its highest effi ciency when IF DISCONNECTION OF THE RESTRAINT IS NECES- properly leveled. Place a level on fryer vessel from SARY, IT MUST BE RECONNECTED WHEN THE FRYER IS RETURNED TO ITS ORIGINALLY INSTALLED POSI- side to side.
  • Page 6: Gas Leak Testing

    • BEFORE OPERATING THIS FRYER, CHECK PIPE ALWAYS disconnect fuel source and power supply JOINTS FOR LEAKS BY USING A SOAP AND WATER before servicing. SOLUTION ONLY. DO NOT USE AN OPEN FLAME! NEVER move a fryer when full of oil. ON AN AA OR CMG (MILLIVOLT) FRYER, DO NOT NEVER introduce objects or liquids into fryer, while SHORT GAS VALVE TERMINALS WHEN TESTING...
  • Page 7: Filling

    GAS FRYER - SERIES 2000  OPERATING FILLING NOTE: Before fi lling the fryer make certain the fryer vessel is sanitized, dry and the drain valve is com- pletely closed. NOTE: We recommend that solid shortening not be used in AA and CMG Model fryers as they are not equipped with a melt cycle.
  • Page 8 (See lighting instructions plate attached to the inner BB MODELS OPERATING INSTRUCTIONS door of Keating Gas Fryer.) Model AA does not require an electrical connection. DO NOT START FRYER WITHOUT FIRST FILLING FRYER Make sure that the Keating Gas Fryer is plugged in. If not your fryer will not operate.
  • Page 9: Cooking

    GAS FRYER - SERIES 2000 5. Set thermostat to desired temperature. • CARE SHOULD BE TAKEN WHEN LOWERING BAS- KETS INTO FRYER TO PREVENT SPLASHING HOT OIL 6. Set “MELT-IDLE-FRY” switch to “FRY” with oil in FROM FRYER VESSEL. the fry pot. The burners will come on. Select “MELT”...
  • Page 10: Oil Breakdown

    B. How to program the “Keating” Electronic Timer DIGITAL TIMERS The electronic timers, standard on TS & IFM models, provide a clearly visible and accurate display and are very easy to use. PROGRAMMING To program the timers, the unit must be in the idle mode.
  • Page 11: Draining

    GAS FRYER - SERIES 2000 1. Contact with Oxygen A DRAIN PIPE AND COVERED CONTAINER SUITABLE FOR USE WITH HOT OIL SHOULD BE USED 2. Carbonization of Crumbs and Food Particles WHENEVER A FRYER IS DRAINED. ALWAYS DRAIN 3. Non-Stainless Steel Surfaces OIL INTO A COVERED RECEPTACLE.
  • Page 12 6. Set thermostat and turn fryer on to bring water to SAFE & EASY® FILTER (SIDE VIEW) a gentle boil. 7. Once boil has been reached, turn fryer off. 8. Dissolve 2/3 cup of Keating Sea Powder for every fi ve gallons of water and let soak for 1/2 hour. If there is a large build-up of carbonized grease, allow fryer to soak overnight.
  • Page 13: Warranty Repairs

    In the event that your Instant Recovery® Fryer, under warranty, needs repairs other than routine cleaning, 12. Close the drain valve and disconnect the clean- you are requested to contact KEATING OF CHICAGO, ing hose. INC. (1-800 KEATING). 13. Check thermostat bulb positioning (should be 1 Figure 5 paper thickness away from heat tube).
  • Page 14: Thermostat Calibration

    3. Place an accurate thermometer in the oil at the PREVENTATIVE MAINTENANCE CHART tip of the thermostat bulb. Left front corner of fryer TIME FRAME OPERATOR/OWNER vessel at the High Limit Bulb is recommended. AT LEAST • Check lights and controls. NOTE: Locate thermometer in same position for DAILY* •...
  • Page 15 In the event that your Instant Recovery® Fryer, under warranty, needs repairs other than routine cleaning, 1. Rotate the thermostat shaft until an audible click you are requested to contact KEATING OF CHICAGO, is heard. INC. (1-800 KEATING). 2. Rotate the thermostat shaft left and right ten times causing the switch to click on and off ten times, while using the Multimeter to verify continuity.
  • Page 16: Service

     SERVICE DIAGNOSIS The following diagnosis is only to be used as a guide to qualifi ed service personnel. Keating recommends that you use a qualifi ed & licensed service company. (Equipment still under warranty requires it.) Call 1-800-KEATING if you need assistance in locating a qualifi ed service company. NOTE: To correctly and quickly diagnose the system, the chart below should be followed in sequential order.
  • Page 17: Ordering Parts

    GAS FRYER - SERIES 2000  ORDERING PARTS Parts may be ordered by calling 1-800-KEATING or your local Keating service company. We recommend using genuine Keating Replacement Parts - engineered and manufactured specifi cally to meet exact specifi cations and requirements for Keating equipment.
  • Page 18 ELECTRICAL BOX ASSEMBLY GAS FRYER CONTROL PANEL TS GAS (TS and BB ONLY) CONTROL PANEL FRONT B, C BACK PANEL ITEM QTY DESCRIPTION TRANSFORMER 120V/240V TO 24V 032408 2 PIN CONNECTOR 032207 9 PIN CONNECTOR 028303 FAT MELT 24V 034272 ITEM QTY DESCRIPTION THERMOSTAT DIAL PLATE 375°...
  • Page 19 GAS FRYER - SERIES 2000 POT ASSEMBLY 14AA GAS POT ASSEMBLY 18AA GAS (Front Drain Shown) (Front Drain Shown) ITEM QTY DESCRIPTION ITEM QTY DESCRIPTION 3 FIN RADIANT 000041 POT WELDMENT 3 FIN RADIANT 000041 18" GAS 1-800-KEATING POT WELDMENT BURNER 028048 14"...
  • Page 20 POT ASSEMBLY 20AA GAS POT ASSEMBLY 24BB & 24TS GAS (Front Drain Shown) (Front Drain Shown) ITEM QTY DESCRIPTION ITEM QTY DESCRIPTION 3 FIN RADIANT 000041 3 FIN RADIANT 000041 POT WELDMENT POT WELDMENT 20" GAS 1-800-KEATING 24" GAS 1-800-KEATING BURNER 028048 BURNER...
  • Page 21: Wiring Diagrams

    GAS FRYER - SERIES 2000  WIRING DIAGRAMS AA 2000 ELECTRICAL ASSEMBLY BB 2000 ELECTRICAL ASSEMBLY 1-800-KEATING...
  • Page 22 TS 2000 ELECTRICAL ASSEMBLY (not shown to scale) BB ELECTRICAL ASSEMBLY WITH SAFE AND EASY® FILTER (not shown to scale) keatingofchicago.com...
  • Page 23 GAS FRYER - SERIES 2000 TS ELECTRICAL ASSEMBLY WITH SAFE & EASY® FILTER BASKET-LIFT ELECTRICAL ASSEMBLY (ALL FRYERS) 1-800-KEATING...
  • Page 25 CUSTOM PASTA FILTER SYSTEM TOP-SIDE COOKER HOTPLATE I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS. SIGNED: DATE: KEATING OF CHICAGO, INC. 1-800-KEATING 8901 West 50th Street PHONE: 708-246-3000 McCook, IL 60525-6001 FAX: 708-246-3100 Serving Those Who Serve the Very Best...