en | Connection
Use the 6-bit dip switch (Camera Control Protocol Switch) to set the camera's control
protocol and its baud rate. If protocol "Pelco D" is selected, which is switch no. 01 and baud
rate 4800, for instance, set the SW-1 to "ON" and the rest to "OFF" as shown below.
6
For more switch configurations, refer to Appendices, page 69.
5.5

Power Connector

Before connecting the power wires, refer to the illustrations below for definition of the power
connector. Be sure to connect to the correct position.
Power
Connector
5.6

Alarm I/O

The camera supports 4 digital alarm inputs and 2 digital alarm outputs. Make sure the alarm
connections are properly wired before starting to configure alarm related settings. Refer to
the pin definition table below for alarm system wiring.
1
2
3
4
5
6
2013.07 | 1.3 |
5
4
3
2
1
Switch
Number
SW1
SW2
SW3
ALARM_OUT_NO_1
ALARM_OUT_NC_1
ALARM_OUT_COM_1
GND
ALARM_OUT_NO_2
ALARM_OUT_CN_2
Description
AC 24V_1 (24 VAC)
GND (Ground)
AC24V_2 (24 VAC)
7
ALARM_OUT_COM_2
8
GND
9
ALARM_IN_4
10
ALARM_IN_3
11
ALARM_IN_2
12
ALARM_IN_1