Sony SVT-S480ES Operating Instructions Manual page 56

Time lapse videocassette recorder
Hide thumbs Also See for SVT-S480ES:
Table of Contents

Advertisement

Available languages

Available languages

RS-232C/RS-485 Interface
RS-232 Interface
When the personal computer is connected to the RS-
232C connector, the transmission speed (baud rate)
can only be set using the GENERAL SET menu.
1
Set the RS-485/RS-232C selector at the rear to
RS-232C.
2
Turn on the power of the equipment to be used.
3
Press MENU and MENU V until "4" of the MAIN
MENU flashes.
4
Press MENU B.
The GENERAL SET menu appears.
GENERAL SET
REC MODE
SP
TAPE
T–120
TAPE IN
MODE
STOP
TAPE END MODE
REW
TAPE USED COUNT
OFF
CLOCK ADJUST
0 1 : 0 0
APC
ON
THREAD CHECK
OFF
T/D SEARCH
CONVENTION
PB S–VHS
AUTO
BAUD RATE
1 9 2 0 0
<NEXT PUSH
>
+
SELECT :
DATA SET :
/
RETURN : MENU
5
Press MENU V to move the flashing to BAUD
RATE and set the baud rate (19200, 2400, 4800 or
9600 bps) by pressing MENU + or –.
C OC
JUS
0
0 0
APC
ON
THREAD CHECK
OFF
T/D SEARCH
CONVENTION
PB S–VHS
AUTO
BAUD RATE
1 9 2 0 0
<
>
NEXT PUSH
+
SELECT :
DATA SET :
/
RETURN : MENU
6
Press SEARCH/AUDIO ON to return to the
normal display.