Optional Elbow Flue Adapter Installation; Securing Stove Pipe/Liner To Flue Collar; Leveling Legs - Quadra-Fire VOYAGEUR GRAND INSERT GRAND-MBK-AU Owner's Manual

Automatic combustion control (acc)
Table of Contents

Advertisement

R
B. Optional Elbow Flue Adapter Installation
Optional use of a Simpson Duravent 15° Universal Elbow
Part Number 4615 may be purchased directly through your
local Simpson Durvent Pipe Distributor or from your local
Quadra-Fire dealer, Part Number DV-4615.
Figure 20.1 shows a vertical installation and also how to
create an optional 30° elbow installation.
The 15° elbow may be secured directly to the flue collar.
Follow the pipe manufacturer's instructions for using
screws or rivets for attachment. Most pipe manufacturer's
152 mm diameter flue liners may be attached directly to the
top of the 15° elbow.
A
Vertical
Figure 20.1
A
Flue
Adapter
Vertical
344 mm
30 Degree
371 mm
April 29, 2013
B
A
o
30
30 degree
B
532 mm
525 mm
C. Securing Stove Pipe/Liner to Flue Collar
1. There are 4 pre-drilled holes in the flue collar 90° apart.
Attach the flue collar to the stove pipe/liner. If the seal is
questionable use stove mastic Figure 20.2
2. Attach gasket to bottom side of flue collar with a thin coat
of silicone.
Flue Collar
Figure 20.2
D. Leveling Legs
1. Remove the 2 screws already installed on each leg.
B
2. Move legs to the desired height.
3. Re-install the screws to secure in place.
Figure 20.3
7075-205
Voyageur Grand
Gasket
Stove Pipe/Liner
Remove 2 screws from both sides.
Adjust the legs up or down to level
appliance.
Page 23