HP AA-RSTZB-TE Installation Manual page 57

Edge switch 2/32
Table of Contents

Advertisement

R_A_TOV
Configure resource allocation time-out value (R_A_TOV) in tenth-of-a-second
increments. This variable works with the error detect time-out value (E_D_TOV)
variable to control the switch's behavior when an error condition occurs. Resources
are allocated to a circuit when errors are detected and are not released for reuse until
the time set by the R_A_TOV value expires. The default value is 100 tenths (10
seconds). Set a value between 10 tenths and 1200 tenths (1 through 120 seconds).
NOTE: Set the same value for R_A_TOV on all directors and switches in a multiswitch fabric. If
the value is not the same on all units, the fabric segments. Also, the value for R_A_TOV must be
greater than the value configured for E_D_TOV.
E_D_TOV
Adjust the E_D_TOV in tenth-of-a-second increments. An error condition occurs
when an expected response is not received within the time limit set by this value. The
default value is 20 tenths (2 seconds). Set a value between 2 tenths through 600 tenths
(.2 through 60 seconds).
NOTE: Set the same value for E_D_TOV on all switches and directors in a multiswitch fabric. If
the value is not the same, the fabric segments.
Switch Priority
Setting this value determines the principal switch for the multiswitch fabric. Choose
Principal (highest priority), Default, or Never Principal (lowest priority) from the
Switch Priority drop-down list.
Setting these priority values determines the principal switch selected for the
multiswitch fabric. For example, if you have three switches in the fabric and set one as
Principal, one as Default, and one as Never Principal, the unit set to Principal
becomes the principal switch in the fabric.
If all switches are set to Principal or Default, the switch with the highest priority and
the lowest WWN becomes the principal switch. Following are some examples of
principal switch selection when switches have these settings:
If you have three switches and set all to Default, the switch with the lowest WWN
becomes the principal switch.
If you have three switches and set two to Principal and one to Default, the switch
with the Principal setting that has the lowest WWN becomes the principal switch.
edge switch 2/32 installation guide
Installing and Configuring the Edge Switch 2/32
2-31