Lamp

Lamp information light output switching.
All information about the lamp is stored inside the lamp house and can be displayed via the projector software on the projection screen.
No information can be changed.
The Constant light output function can be changed between yes and no.
How to display the lamp menu.
1
Push the cursor key é or ê to highlight 'Lamp' (menu 1).
2
Press ENTER to select.
The lamp menu will be displayed (menu 2)
Which information is available ?
Serial number : unique serial number of the lamp.
Type : lamp type.
Run time : total time the lamp is used in this or other projectors.
Remaining run time : time left before the lamp must be replaced
Using the lamp longer than the maximum run time (1500 hours) may damage the projector.
Number of strikes : Total times the lamp is started up.
Z-AXIS : indication to adjust the Z-AXIS of the lamp (see Re-adjustment of the lamp position in chapter Installation Guidelines).
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
LAMP
MORE...
Select with é or ê
then <ENTER>
<EXIT> to return.
menu 1
How to switch the constant light output ?
1
Push the cursor key é or ê to highlight 'Constant Light Output' (menu 1).
2
Press ENTER to toggle between [YES] and [NO].
[YES] : constant light output, power will be adapted.
[NO] : fixed power, no power adaptation.

BARCO logo

What can be done ?
The BARCO logo can be added to the image, in overlay or on a background, on any place on the screen.
How to add or the change the settings ?
To add the BARCO logo or to change a setting in the BARCO logo menu:
1
Push the cursor key é or ê to highlight 'BARCO logo' (menu 1).
2
Press ENTER to select.
The BARCO logo menu will be displayed on the screen (menu 2. Within this menu, three toggle settings and a shift control are
available.
SERVICE
BARCO LOGO
ADD-INS
PRESET INPUT BALANCE
DIAGNOSIS
MORE...
Select with é or ê
then <ENTER>
<EXIT> to return.
menu 1
5976229 BARCO SLM G5 10052001
LAMP
Constant light output [YES]
Serial number : R101111
Article number : R9840740
Run time : 10 hours
Remaining run time : 490 hours
Number of strikes : 10
Z-AXIS : 100
Select with é or ê
<ENTER> to toggle
<EXIT> to return.
menu 2
BARCO LOGO
STATUS : [ON]
BACKGROUND : [ON]
SHIFT
HOT KEY : [TEXT]
Select with é or ê
then <ENTER>
<EXIT> to return.
menu 2
Service Mode