Supply cable of the machine must have copper wires. The cross section of the supply wires depends
on the supply voltage and on the total electrical power input of the machine (see table 4.3). The supply cable
safety device against a short-circuit fault and overloading must be performed by automatic breakers or fuses
in the laundry switchboard. The recommended minimal cross-section of the supply wires as well as the values
of fuses (F) for the supply are stated in table 4.5.
In all cases were the local standards requirements are higher, these has to be followed above the recommendation
in table 4.5. If the local standards require installation of the earth leakage trip, we suggest to install one of 100 mA
for the machines equipped with frequency inverter. The main contacts of the earth leakage trip must comply
with the specified power input of the machine.
Power supply
protection (A)
16
25 - 32
40
50
60 - 80

4.5.4. INSTALL SUPPLY CABLE TO THE MACHINE

WARNING !
!
THE PROTECTIVE CONDUCTOR MUST BE LONGER SO THAT WHEN THE CABLE IS PULLED OUT
ACCIDENTALLY, THIS CONDUCTOR IS DISCONNECTED AS THE LAST ONE!
Push the cable through the turnbuckle and connect the wires with the main switch. The diameter of the supply
cable must between 11-17mm / 0.43-0.67" for M25 turnbuckle and between 12-21mm / 0.47-0.83" for M32
turnbuckle. Conductors of the supply cords shall not be consolidated by lead-tin soldering where they are subject
to contact pressure, unless the clamping means is constructed so that there is no risk of a bad contact due
to cold flow of the solder. The phase terminals are marked by L1, L2 and L3. A separate insulated terminal,
labeled N, is provided for the neutral wire. Connect the protection earth wire directly to the protection earth
terminal (marked PE) located on the rear bridge. Tighten the cap nut of the turnbuckle. By this way the rubber
ring in the turnbuckle is pressed, thus securing the cable mechanically and against water. If there's no main
switch the terminals are marked in the same way so also the connection is the same. Depending on your supply
voltage it is possible that L2 and L3 (1 AC) or N (3 AC without Neutral) must not be connected.
If the cable is attached from above, it is recommended to make a sagging on the cable in front of its entry
into the cable turnbuckle. In this way an ingress of the running condensed water into the bush and/or machine
can be avoided. The manufacturer recommends to attach the cable from beneath.
1. L1, L2, L3 and N terminal
2. Turnbuckle
3. Turnbuckle nut
4. PE terminal
100646 PUBLICATION DATE Sep 05
Recommended phase
conductor section
2
(mm
)
2,5
4
6
10
16
Tab 4.5.A. Recommended minimal conductor section
Fig. 4.5.B. Example of supply cable connection
INSTALLATION AND MAINTENANCE MANUAL
Protection conductor
2
section (mm
)
2,5
4
6
10
16