Troubleshooting Aids; Error Handling; Problem Check List - Maytag MFS 25 Installation And Maintenance Manual

Commercial washer
Hide thumbs Also See for MFS 25:
Table of Contents

Advertisement

6. TROUBLESHOOTING AIDS

6.1. ERROR HANDLING

The timer allows the full control of the washing machine. When an error occurs then automatically the machine
will go over to a safe state. With the diagnostic program you can determine the problem (See „Programming
manual"). This program will test all the functions of the washing machine.
If a failure occurs then the computer will display a diagnostic message. The message is a number that correspond
with a typical problem.
If a failure occurs and the timer gives no message you can consult chapter 6.2.

6.2. PROBLEM CHECK LIST

Problem
When the power is switched on :
the display is not lighting up
Remark :
The display must always light up
when the power connector is
connected to the power board
(EPROM with software must be
implemented)
The machine is not starting up when
the start button is pressed.
Coins are inserted but the displayed
program price is not counting down
Coindrop is accepting coins but does
not start the washer
The machine is not responding on
pressing the keyboard buttons
The dot to indicate that the software is
in program mode can not be enabled
or disabled
24
Cause
• no external power
• the emergency button is activated
• the power connector is not
connected on the board
• the power connector is inverse
connected
• the fuse on the PWR board has
jumped
• the input connector is disconnected
• the EPROM that contains the
software is not implemented
• the key switch stands in Program
mode
• the correct amount of coins is not
inserted
• the door is not closed properly
• the micro contact mounted on the
coin drop is not functional
• the optocoupler mounted on the
coindrop is not functional
• check the wiring to the coindrop
• verify if you have entered a coin
value in the u-submenu for the
corresponding coindrop
• the start button is not pushed after
the amount is flashing on '00'
• the right amount is not reached
• the door is not closed properly
• the key switch is not functional (no
dot is displayed when switching in
Program mode)
• the START button is not functional
(the key switch stands in Program
mode)
• the SET button is not functional (the
key switch stands in Run mode)
• no button is functional and the key
switch is in the right position
• the key switch is not functional
• the infrared key is not functional
INSTALLATION AND MAINTENANCE MANUAL
Solving the problem
• verify the external tension of the
machine
• deactivate the emergency button
• connect the power connector
• check the wiring and connect the
connector as it must be
• if the transformer is deformed replace
the PWR board
Check the wiring and the tension at the
power Connector
If the transformer is still OK change the
Fuse
• if the display is lighting up: verify that
the input signals or the + 16 V signal are
not touching the cabinet
• put the right EPROM with software into
the socket on the board.
• set the Key switch to Run mode
• the start button must be pressed when
00 is flashing on the lower display
• close the door
• verify the well functioning of the micro
contact of the coindrop :
positive pulses should be generated
• verify the well functioning of the
optocoupler positive pulses should be
generated
• if the wiring is broken: repair the wiring
• insert the correct coin value in the u-
submenu
• push the start button
•Put the right amount in the coindrop
• close the door
• check if the input connector A is well
connected and check the wiring between
the input connector and the keyswitch
• set the Key switch to Run mode
• set the Key switch to Program mode
• check if the connector K of the keyboard
is well connected
• check if the input connector A is well
connected and check the wiring between
the input connector and the keyswitch
• set the menu-item, Ir = On
PUBLICATION DATE Sep 05
100646

Hide quick links:

Advertisement

Table of Contents
loading