Problem
The machine is not behaving as
expected
A program is started, but the outputs
are not activated
Dashes are displayed and on the
lower display a counter is counting
down
Wrong water level
(the water level sensor must not be
calibrated)
The process is stopped and there is
still water in the drum
The water does not stay in the
machine
Machine is not filling or filling time is
too long
Machine is filling with water in the
'OFF' position
Machine is leaking
There is a door seal leakage
There is no warm water in the wash
sequence
The heating time is too long
There is too much vibration during
extracting
100646 PUBLICATION DATE Sep 05
Cause
• if the wrong machine type is
selected the wrong outputs will be
activated
• the suspension is not working, the
shock absorbers are cold
• check if connector R and Q are
connected
• check if connector R and Q are not
inverted
• this is a wait state caused by a
power interruption or a safety
sequence at the end of the process
• check if the programmed water
levels in the P-submenu are the
correct ones
• check if the right machine type is
selected in the S-submenu
• you have changed the machine type
but the standard water levels are not
changed
• you can start a new program and
advance the program to the tumble
sequence
• the drain is stopped up
• the drain valve is blocked
• the drain valve is not closing
• leakage of rubber between tub and
drain valve
• inlet taps are closed
• water pressure too low
• water is blocked somewhere
• inlet valve filter is blocked
• inlet valve is damaged
• inlet valve is damaged
• clamps of hoses are not tightened
• some hose is damaged
• sealing is damaged
• supply and drain hoses are not
connected properly
• the door rubber seal is damaged
• insufficient door pressure
• program is not correct
• the hoses are not correct connected
• incoming supply is not warm
• heating elements are defective
• wiring is damaged or wrong
• calcium sediments cover the
heating elements
• bolts of cabinet and reinforcements
are not fixed properly
• vibration switch is not correct
installed
• the suspension is damaged, the
INSTALLATION AND MAINTENANCE MANUAL
Solving the problem
use the key switch at a distance less
then 0,5 meter and in front of check the
battery (the LED of the infrared key is
eluminated when the button is pressed)
• check if the right machine type is
selected in the S-submenu
• change shock absorbers or springs
• connect the connector at the correct
position
• Pin Q10 must be supplied with 220Vac
when the door is closed
• wait until the counter has reached 0
• do not switch of/on the power again as
you will restart the counter
• set the right water levels
• select the right machine type in the S-
submenu
• the standard water levels can only be
reinitialised by changing the program Set
in the S-submenu : standard wash
• advancing a program : turn the key
switch in program-mode and press the
start button
When the water is drained you can open
the door
• clean the drain
• clean the drain valve
• check wiring from drain valve
• change drain valve when broken
• Replace rubber piece
• open inlet taps
• look at your supply installation
• check for kinks in the inlet hose
• close water inlet and clean filter
• replace inlet valve
• replace inlet valve
• tighten the clamps
• replace the hose
• change the sealing
• connect the hoses properly
• change the door rubber seal
• remove spacers from behind the hinges
• change program to correct temperature
• connect the supply hoses correctly, the
incoming supply to the warm water inlet
valve.
• use warm water supply, check your
warm water installation
• change heating elements
• check, replace or repair wiring
• clean or replace the heating elements
• tighten the bolts
• reinstall vibration switch