3.2.6 To Read Audio Volume Units (VU) of output #1

This command returns the height of hypothetical bar LED indicator having a
height of 16 segments. It will return a number from 0 to 16 with 10 being 0 db
level. So if the output #1 is at 0 dB (900 mv p-p sinewave) it returns 10. See
figure 11 for 16x16 row. This value is 0-16 regardless of the type of matrix.
RB<cr>
Command:
0 ~ 16<cr>
Response:

3.2.7 To Read Temperature inside the Matrix

RT<cr>
Command:
Response:
Temperature in degrees C = 32.500000<cr>
Temperature in degrees F = 90.500000<cr>

3.2.8 To Read the Firmware Version

RI<cr>
Command:
Response:
Unit's name:
Version 2.3
Build # 7
BBox-I-A-8-8

3.2.9 To Read Supply Voltages

The supply voltages consist of clock battery voltage, 5V supply, and 12V supply.
RV<cr>
Command:
Response:
RTC Battery Voltage = 2.9876704
+5V Supply = 4.9473252
+12V Supply = 12.4646893

3.2.10 Real Time Clock Functions

3.2.10.1 To set date & time:
DS<cr>
Command:
Response:
Friday 04/18/08 12:27:15pm
Enter the year (00-99):
Enter the month (01-12):
Enter the date (01-31):
Enter the day of the week (1=Sun – 7=Sat):
Enter the hour (1-12):
Enter the minute (00-59):
stands for Read Bar
stands for Read Temperature
stands for Read Identity
← User defined name of the unit
← Firmware Version
← Build number (for mfg purposes only)
← Characteristics of the unit
stands for Read Voltages
stands for Date Set
Hit Enter if you want to keep previous value; hit Esc to exit
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

1121a1122a1123aAc1121aAc1122aAc1123a

Table of Contents