Alarm ID
Message Name
410
Open Low Pressure Switch
411
Low Pressure Switch Strikes Lockout
412
Open High Pressure Switch
413
High Pressure Switch Strikes Lockout
414
High Discharge Line Temperature
415
High Discharge Line Temperature Strikes Lock-
out
416
Outdoor Coil Sensor Faulty
417
Discharge Sensor Faulty
418
W Output Hardware Fault
419
W Output Hardware Fault Lockout
420
Defrost Out of Control
421
W External Miswire Alarm
530
Damper End Switch Failed to Close
531
Damper End Switch Failed to Open
532
Damper Control Module Alarm
594
Discharge Air Temperature Sensor Problem
700
Comfort Sensor Temperature Sensor Problem
701
Comfort Sensor Temperature Too High
702
Comfort Sensor Temperature Too Low
703
Comfort Sensor Humidity Sensor Problem
704
Comfort Sensor Humidity Too High
705
Comfort Sensor Humidity Too Low
Alarm Codes and Troubleshooting
Action required to Clear/Recover
Remove any blockages or restrictions from indoor coils and/or fans. Check refrigerant charge and system operation.
Check system charge using approach and sub cooling temperatures. Reset by putting outdoor board in test
mode or resetting low voltage power.
Check system operating pressures and compare to unit charging charts.
Check system charge using approach and sub cooling temperatures. Reset by putting outdoor board in test
mode or resetting low voltage power.
Check system operating pressures and compare to unit charging charts.
Check system charge using approach and sub cooling temperatures. Reset by putting outdoor board in test
mode or resetting low voltage power.
Sensor being detected open or shorted or out of temperature range. Board will not perform demand or time/tem-
perature defrost operation. (System will still heat or cool).
The board detects open sensor or out of temperature sensor range. This fault is detected by allowing the unit to
run for 90 seconds before checking sensor resistance. If the sensor resistances not within range after 90 sec-
onds, the board will count one fault. After 5 faults, the board will lockout.
Replace the control board.
Defrost longer than 20 minutes. Check HP operation.
Check and correct the wiring.
Repair/replace damper.
Repair/replace damper.
Check/replace if needed.
Check wiring. Ohm out sensor and check to temperature/resistance chart.
Recalibrate stat to clear, replace thermostat if needed.
Recalibrate stat to clear, cool down stat, adjust setpoint, replace thermostat if needed.
Recalibrate stat to clear, warm up stat, adjust setpoint, replace thermostat if needed.
Recalibrate stat to clear, adjust setpoint, replace thermostat if needed.
Recalibrate stat to clear, replace thermostat if needed.
Recalibrate stat to clear replace thermostat if needed.
Page 35