Alarm ID
Message Name
313
Indoor/Outdoor Unit Capacity Mismatch
345
Relay O Failure
346
HP Jumper not Removed
347
Relay Y1 Failure
348
Relay Y2 Failure
349
IFC Error Check Jumper O to R
350
Electric Heat not Configured
351
Electric Heat Stage 1 Problem
352
Electric Heat Stage 2 Problem
353
Electric Heat Stage 3 Problem
354
Electric Heat Stage 4 Problem
355
Electric Heat Stage 5 Problem
400
LSOM Compressor Internal Overload Tripped
401
LSOM Compressor Long Run Cycle
402
LSOM Outdoor Unit System Pressure Trip
403
LSOM Compressor Short−Cycling
404
LSOM Compressor Rotor Locked
405
LSOM Compressor Open Circuit
406
LSOM Compressor Open Start Circuit
407
LSOM Compressor Open Run Circuit
408
LSOM Compressor Contactor Welded
409
LSOM Compressor Voltage Low
506052−01 11/09
Alarm Codes and Troubleshooting
Action required to Clear/Recover
Incorrect indoor/outdoor capacity code selected. Check for proper configuring in installation instructions. Alarm
is just a warning. The system will operate, but might not meet efficiency and capacity parameters and alarm
would clear when commissioning is exited.
O relay / Stage 1 failed (Pilot relay contacts did not close or the relay coil did not energize),
Configuration jumper(s) not removed on control board cut O−R. Applicable with non communicating outdoor unit
with communicating indoor system.
Y1 relay / Stage 1 failed (Pilot relay contacts did not close or the relay coil did not energize),
Y2 relay / Stage 2 failed (Pilot relay contacts did not close or the relay coil did not energize),
Configuration link R to O needs to restored Applicable in non communicating mode,
Heat call with no configured or mis−configured electric heat. Check for proper configuring under Configuring
Electric Heat Stages in the air handler installation instructions.
Heat section / Stage 1 failed (Pilot relay contacts did not close or the relay coil in the electric heat section did
not energize).
Heat section / Stage 2 failed (Same as Code 351).
Heat section / Stage 3 failed (Same as Code 351).
Heat section / Stage 4 failed (Same as Code 351).
Heat section / Stage 5 failed (Same as Code 351).
Compressor protector is open. Check for high head pressure, check compressor supply voltage.
Outdoor unit power disconnect is open.
Compressor circuit breaker or fuse(s) is open.
Broken wire or connector is not making contact.
Low or high pressure switch open if present in the system.
Compressor contactor has failed to close.
Compressor ran over 18 hours on one room thermostat demand.
Outdoor unit pressure trip. Check dirty coil, fan motor, refrigerant charge.
Compressor short cycling (Running less than 4 minutes).
Check capacitor, wiring, hard−start kit, replace compressor.
Check compressor for hot (cool down), check pressures, fan motor etc. Replace compressor if unable to get
circuit to close and compressor to operate.
Replace contactor.
Check power to unit.