Parameter Name
Parameter Name
High Cooling Airflow
(CFM @ 100% cool)
Low Cooling Airflow
(CFM @ lowest cool stage)
Airflow Profile − Cooling
High Heat Pump Airflow (CFM @
100%)
Low Heat Pump Airflow (CFM @ lowest
stage)
Equipment Name
Continuous Indoor Blower Airflow
Humidification Airflow
Dehumidification Airflow Percentage
Note 1: Minimum Outdoor Unit Cooling Stage as a percentage of High Cooling Airflow (value is rounded up to the closest number on 25 CFM resolution
Note 2: Minimum Outdoor Unit Heating Stage as a percentage of High Heat Pump Airflow (value is rounded up to the closest number on 25 CFM resolution).
Note 3: All communicating Installer Parameters default CFM values based on DIP switch setting (non−communicating value) are calculated using the CFM conversion tables and
rounded up to closest number on 25 CFM resolution.
Note 4: Parameter dependency − Certain parameters are dependent on others and may not be shown on the display.
Note 5: Default Values − Jumper/DIP switches impact the default value of some parameters.
Value
Default
Min.
Cooling Airflow Setting
OU tons (OUNC) *
Min CFM
Max CFM
400CFM
Min CFM
Max CFM
See Note1 below
Min CFM
Max CFM
Min CFM
Max CFM
DIP SW
0
Heat Pump Airflow Setting
OU tons (OUNC) *
Min CFM
Max CFM
400CFM
Min CFM
Max CFM
See Note 2 below
Min CFM
Max CFM
Min CFM
Max CFM
Furnace
N/A
DIP SW (See
Min CFM
Max CFM
Note 3)
Min CFM
Max CFM
Same as above
Min CFM
Max CFM
Min CFM
Max CFM
140
120
(=70%)
(=60%)
(=80%)
Max.
Incr.
Dependency
Dependency
25
Outdoor Unit present
25
25
2+ stage Outdoor Unit present
25
3
1
Outdoor Unit present
25
Heat Pump present
25
25
2+ stage Heat Pump present
25
Other Parameters
N/A
N/A
None
25
None
25
25
Humidifier present
25
160
2
OU present AND SC algorithm support
(=1%)
Page 29
Note
Note
1/2 HP blower
1 HP blower
1/2 HP blower
1 HP blower
0–Text ID 0x0105
(A:ON:50%/30s,82%/7.5min
OFF:50%/30s)
1–Text ID 0x0106 (B:ON:82%/7.5min;
OFF: No delays)
2–Text ID 0x0107 (C:ON: No delays;
OFF: 45sec delay)
3–Text ID 0x0108 (D:No delays)
1/2 HP blower
1 HP blower
1/2 HP blower
1 HP blower
Up to 35 characters
1/2 HP blower
1 HP blower
1/2 HP blower
1 HP blower
Percent of High Cooling Airflow
icomfortt Touch Screen 7−Day Programmable Thermostat