Parameter
1-255 = Seconds
Values:
30 = Default value

Comma Dial Modifier Timer

This command allows the DTE to set the duration of the pause associated with
a comma (,) dial modifier.
Command
Action
AT+s8<timer>
Query
AT+s8?
Range
AT+s8=?
Parameter
0-255 = Seconds
Values:
2 = Default value

Circuit Data Idle Timer

This command specifies an idle line timeout for online data mode. If no data is
sent by the DTE on the transmit data line for the specified period of time, the
DCE disconnects the call, returns the OK result code, and returns to command
mode.
Command
Action
AT+s30<timer>
Query
AT+s30?
Range
AT+s30=?
Parameter
0-255 = Seconds
Values:
0 = Default value