Page 2
Table of Contents Table of Contents Command Line Interface ......................2 Introduction ..........................2 Command Lists ......................... 3 Metered ATS Command Line Interface User Guide...
Command Line Interface Command Line Interface Introduction How to log on Users can log on to the command line interface through local access (Serial port). 1. Local access to the command line interface To log on via serial connection, the PC/server must be connected directly to the Universal port of the PDU using the included RJ45/DB9 Serial Port Connection Cable, and perform the following steps.
To display load configuration of the device CyberPower > devcfg show Example 2: To set overload threshold at 7500W CyberPower > devcfg overload 7500 Example 3: To set near overload threshold at 5000W CyberPower > devcfg nearover 5000 Example 5: To set idle time of the device at 10 minutes CyberPower >...
Page 5
CyberPower > bankcfg show Example 2: To set overload threshold of bank 1 at 15A CyberPower > bankcfg index b1 overload 15 Example 3: To set near overload threshold of bank 2 at 10A CyberPower > bankcfg index b2 nearover 10 srccfg Description: Show and set the source configuration.
Page 6
Command Line Interface To set preferred source of the device to be Source B CyberPower > srccfg prefer b Example 3: To set frequency deviation to be +/- 2Hz CyberPower > srccfg freqdeviation 2 Example 4: To set device voltage sensitivity to be Low CyberPower >...
Page 7
Command Line Interface CyberPower > sys reset all login Description: Show and configure authentication for login. Option Argument Description name <administrator account> Set user name of admin <administrator passwd Set user password of admin password> The period (in minutes) that the system waits before...
Page 8
Contact Information Feel free to contact our Tech Support department with installation, troubleshooting, or general product questions. Cyber Power Systems, Inc. Web: www.cyberpower.com For USA and Canada: 4241 12th Ave East, Suite 400 Shakopee, MN55379 Toll-free: (877) 297-6937 For all other regions: Please visit our website for local contact information.