SmartNode 4900 User Manual
Connecting a 10/100Base-T Ethernet port to an Ethernet-capable workstation. The 10/100Base-T Ether-
net ports can connect to a single Ethernet-capable workstation or PC by means of any Ethernet cable.

Connecting the EIA-561 RS-232 configuration port (DCE configured)

Install the supplied RJ-45-to-RJ-45 cable with the DB9-RJ45 adapter between the SN4900 IpChannel Bank
RS-232 console port
(figure
cable, refer to the pinout diagram in

Connecting the serial port

Serial devices (V.35 or X.21) are connected to the SmartNode's serial ports (see
at the SmartNode 4900. The V.35 connector is a DB-25 female and the X.21 uses a DB-15 female. The sync
serial ports are configured as DTE.
V.35 Interface (DB-25)
Pin
1
Frame Ground
2
TD-a (to DCE)
3
RD-a (from DCE)
4
RTS (to DCE)
5
CTS (from DCE)
6
DSR (from DCE)
7
Signal Ground
8
CD (from DCE)
9
RC-b (from DCE)
11
XTC-b (to DCE)
12
TC-b (from DCE)
14
TD-b (to DCE)
15
TC-a (from DCE)
16
RD-b (from DCE)
17
RC-a (from DCE)
20
DTR (to DCE)
Installing the IpChannel Bank
10) and an open serial port on your computer. If you need to assemble your own
figure
10.
RJ-45 Jack
1
2
3
4
5
6
7
8
Figure 10. DB-9-to-RJ-45 cable diagram
Table 8. Serial port pin-outs
Description
DB-9
Signal Name
6 DSR
1 CD
DSR & DTR are internally
wired together
4 DTR
5 SG
2 RD (driven)
3 TD (received)
8 CTS
7 RTS
X.21 interface (DB-15)
Pin
Description
1
Signal Ground
2
Transmit (to DCE)
3
Control (to DCE)
4
Receive (from DCE)
5
Indication (from DCE)
6
Signal Element Timing (from DCE)
8
DTE Common Return
9
Transmit (to DCE)
10
Control (to DCE)
11
Receive (from DCE)
12
Indication (from DCE)
13
Signal Element Timing (from DCE)
3 • Hardware installation