40
Optional Equipment (for qualified installers only)
7. Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice
Lift the pilot hood
a
off the pilot
assembly.
8. Replace the firebox components.
9. Remove the four screws holding the control cover in place (see picture below). Pull the control cover
forward slightly and disconnect the flame height knob (do not remove the knob). This allows the
control cover to move upwards, away from the concealment cover.
10. Pull the control cover forward, taking care to not damage any wiring (see picture below). This will
allow access to the gas control valve.
© Travis Industries
Remove the orifice and replace with the LP orifice. Screw the
c
orifice all the way in and replace the pilot hood.
Use a hex wrench to
b
unscrew the orifice.
5/32" Hex
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
4120319
Orifice Identification:
LP (Propane) Orifice
35
35
NG (Natural Gas) Orifice
62
100-01237_000