Appendix A.3. Node Status; Appendix A.4. Fieldserver Synchronization - FieldServer FS-8700-130 Notifier NCA2-NFS2-3030 Instruction Manual

Nca2/nfs2-3030 serial driver
Hide thumbs Also See for FS-8700-130 Notifier NCA2-NFS2-3030:
Table of Contents

Advertisement

FS-8700-130 Notifier NCA2/NFS-3030 Manual
System Trouble
LOOP CONTINUITY TEST FAIL LOOP 3
LOOP CONTINUITY TEST FAIL LOOP 4
LOOP CONTINUITY TEST FAIL LOOP 5
LOOP CONTINUITY TEST FAIL LOOP 6
LOOP CONTINUITY TEST FAIL LOOP 7
LOOP CONTINUITY TEST FAIL LOOP 8
LOOP CONTINUITY TEST FAIL LOOP 9
LOOP CONTINUITY TEST FAIL LOOP 10
AMP FAIL
AC FAIL
SCB ASSEM. COM. VERIFIED FAILED
8255 PORT CHIP CONTROL WORD CHECK FAILE
NETWORK COMMUNICATION LINK FAIL PORT A
NETWORK COMMUNICATION LINK FAIL PORT B
STYLE 4 SHORT A L1
STYLE 4 SHORT B L1
STYLE 4 SHORT A L2
STYLE 4 SHORT B L2
STYLE 4 SHORT A L3
STYLE 4 SHORT B L3
STYLE 4 SHORT A L4
STYLE 4 SHORT B L4
STYLE 4 SHORT A L5
STYLE 4 SHORT B L5

Appendix A.3. Node Status

Data for any particular Node is valid while that Node is online and the system is synchronized. Integrity of
data for any Node will be lost if the Node goes offline or if synchronism between the FieldServer and the
NCA2 Panel is lost.
Node status offline/online (1/0) is stored in the 502
before reading any information about the Node.
Node status data integrity itself depends upon system synchronization.

Appendix A.4. FieldServer Synchronization

There is currently no method of auto-synchronizing the FieldServer's Data Arrays with the Notifier NCA2/NFS2-
3030 panel because there is no method for polling the panel through the printer or CRT port. Synchronization of
the two devices can be achieved manually pressing the "System Reset" button on the panel while the FieldServer is
connected and running. All current events will be re-sent to the FieldServer..
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262-2299 Fax: (408) 262-2269 Toll Free: (888) 509-1970 email: support@fieldserver.com
Address
System Trouble
231
WALK TEST - FIRE PROTECTION IS LIMITED
232
REMOTE PROG MODE ACCESSED
233
DIA PROG. CHANGE DET. SERVICE REQUIRED
234
ISIB DATA MESSAGE RECEIVED ERROR
235
ISIB EXECUTIVE ROUTINE RE-ENTERED
236
DIB TO SIB CABLE BAD OR MISSING
237
UPLOAD/DOWNLOAD MESSAGE RECEIVED
238
GLOBAL DATABASE MISMATCH
239
SIB PROG. CHANGE DET. SERVICE REQUIRED
240
HS-NCM SNIFFER MODE ACTIVE
241
EXCEEDED CONNECTION LIMIT
242
NAM CCBE. PROG LOST
243
MEMORY LOSS
244
DVC COMM LOSS
245
A.C. POWER LOSS. BACK UP ACTIVATED
246
BUZZER OFF-LINE
247
PANEL DOOR OPEN
248
OFF NETWORK
249
INSTALL. ERROR
250
OR AUDIO/TELEPHON
251
EXPANDER MODULES
252
MANUAL CONTROL
253
CAT. COMM. FAULT
254
UNKNOWN
nd
address. It is important to read the Node status
Page 18 of 22
Address
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508