16. Servicing
A
Image 16-13
Open reservoir
3. Loosen the bleed lid a little so that air can enter and close the bleed lid again.
4. Turn on the bolt so that the white indication line is in the Open area (membrane is at the bottom of the reservoir).
5. Turn the bleed lid a little and take it out (B)
6. Turn out the third lid using the back of the main lid.
C
Image 16-14
Remove third lid
7. Top-up the reservoir with cooling liquid until the level is somewhat higher than the hole in the reservoir.
Image 16-15
Top-up reservoir
8. Close the third lid again using the back of the main lid. Use a cloth to dab the residue of cooling liquid.
Note: Make sure that no cooling liquid is spilled in the projector.
9. Turn in the bleed lid.
180
B
D
R59770021 CLM R10+ 15/03/2010