5. Connections
Image 5-2
Power input
4. Connect the male side of the power cord to the local power net.
Caution:
Ensure that the power net meets the power requirements of the projector, which are: 100-120/200-240V 12/8A
50/60Hz.
W
ARNING
range.
C
AUTION
imately five minutes to ensure that the projector and lamp have sufficiently cooled, at which point the fans
will automatically decrease to standby. To avoid thermal stress that can lead to premature lamp failure, never
unplug the power cord while the lamp cooling fans are running. Never unplug the power cord to power down
the projector, first switch off the power switch and then unplug the power cord.
Fuses
The projector is protected with an automatic circuit breaker of 20 A which is built in into the power switch.
Power input voltage versus light output
When the input power is between 170V and 264V the maximum light output with 4 lamps can be reached.
In the low input power ranges the light output will be reduced to protect the projector.
When the input power is between 100V and 140V, 75% of the light output with 3 lamps can be reached.
When the input power is between 90V and 100V the light output is reduced to 62.5% with only 3 lamps.
38
:
Do not attempt operation if the AC supply and cord are not within the specified voltage and power
: