Barco R9050100 User Manual page 212

Clm r10+
Hide thumbs Also See for R9050100:
Table of Contents

Advertisement

E. Troubleshooting
Error
Description
code
4198
FPGA PMP init
failed
6099
Board ID
unkown
version
6098
Board ID
invalid string
7999
DMD temp low
7998
DMD temp high
7997
Ambient temp
low
7996
Ambient temp
high
7995
TEC temp low
7994
TEC temp high
7992
LPS1 temp
high
7990
LPS2 temp
high
7988
LPS3 temp
high
7986
LPS4 temp
high
7978
Lamp4 temp
high
7924
Fan radiator A
low
7922
Fan radiator B
low
7920
Fan outlet A
low
7918
Fan outlet B
low
7916
Fan power
supply A low
7914
Fan power
supply B low
7912
Fan LPS A low
7910
Fan LPS B low
208
Error
Warning
Caused by
-
Yes
Yes
Yes
Yes
Yes
Low temperature on DMD
Yes
Yes
High temperature on DMD
Yes
Yes
Ambient temperature out of
specifications
Yes
Yes
Ambient temperature out of
specifications
Yes
Yes
Yes
Yes
High temperature on LPS1
Yes
Yes
High temperature on LPS2
Yes
Yes
High temperature on LPS3
Yes
Yes
High temperature on LPS4
Yes
Yes
High temperature on lamp 4
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Yes
Yes
Fan is running too slow or not at all
Action
turning on the lamp(s) will heat up
the DMD
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
take measurements to increase the
temperature
check ambient conditions
check if air slots are free, clean air
filter.
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
If problem persists, call a qualified
service engineer
R59770021 CLM R10+ 15/03/2010

Advertisement

Table of Contents
loading

This manual is also suitable for:

R90501001Clm r10+ r9050100Clm r10+ r90501001

Table of Contents