If Thermal Protection Mode Step 2 is reached, the internal temperature needs to first decrease
back to the Step 1 temperature and then decrease further to the value required to disable
Thermal Protection Mode 1.
Example of Thermal Protection Mode for an ET4201L Monitor with 100% Brightness:
At Step 1: OSD = 60, Brightness = 80%
Normal operation returns if OSD can maintain 55°C or lower temperature for five
minutes.
At Step 2: OSD = 65, Brightness = 72%
Return to Step 1 if OSD can maintain 60°C or lower temperature for five minutes.
If the monitors internal temperature continues to rise, the monitor will shut off at OSD = 70°C
Table Top Mode
Requirements:
1. The Table Top Mode function on the OSD must be enabled if the unit is placed in table
top orientation.
2. Cooling methods must be put in place in the area below the monitor to prevent the
monitor from overheating. Consult the Elo website for additional information regarding
thermal recommendations for all mounting modes.
Note: The warranty will be void if failure occurs to the monitor in table top mode orientation and
the Table Top Mode function is not enabled without adequate cooling methods installed.
When the monitor is in Table top mode, the Thermal Protection steps are different. These OSD
values are stated in the table below.
Thermal Protection
Monitor
Mode Enabled (°C)
Size
ET32/4201L
ET5501L
ET7001L
Thermal Protection
Mode Enabled (°C)
Step 1
60
57
59
Thermal Protection
Mode Enabled (°C)
Step 2
65
61
64
Auto Shut Off
Temperature (°C)
Step 3
70
n/a
69
User Manual: Interactive Digital Signage
SW601990 Rev F, Page 25 of 36
75
65
74