Thermal Grease - IBM System x3550 M3 Type 4254 Installation And User Manual

1-u-high rack model server
Hide thumbs Also See for System x3550 M3 Type 4254:
Table of Contents

Advertisement

If you have other devices to install or remove, do so now. Otherwise, go to
"Completing the installation" on page 103.

Thermal grease

The thermal grease must be replaced whenever the heat sink has been removed
from the top of the microprocessor and is going to be reused or when debris is
found in the grease.
When you are installing the heat sink on the same microprocessor that is was
removed from, make sure that the following requirements are met:
v The thermal grease on the heat sink and microprocessor is not contaminated.
v Additional thermal grease is not added to the existing thermal grease on the heat
Note:
v Read the Safety information on page vii.
v Read the "Installation guidelines" on page 44.
v Read "Handling static-sensitive devices" on page 46.
To replace damaged or contaminated thermal grease on the microprocessor and
heat sink, complete the following steps:
1. Place the heat sink on a clean work surface.
2. Remove the cleaning pad from its package and unfold it completely.
3. Use the cleaning pad to wipe the thermal grease from the bottom of the heat
4. Use a clean area of the cleaning pad to wipe the thermal grease from the
Fan 6
sink and microprocessor.
sink.
Note: Make sure that all of the thermal grease is removed.
microprocessor; then, dispose of the cleaning pad after all of the thermal grease
Fan tabs
Fan connector on
the system board
Fan 3
Fan 2
Fan 1
Fan connector
Fan (side view)
Chapter 2. Installing optional devices
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3550 m3 type 7944

Table of Contents