IBM System x3550 M3 Type 4254 Installation And User Manual page 44

1-u-high rack model server
Hide thumbs Also See for System x3550 M3 Type 4254:
Table of Contents

Advertisement

AC power-supply LEDs
AC
DC
On
On
Off
Off
Off
Off
Off
On
Off
On
On
Off
On
Off
On
On
The following illustration shows the locations of the power-supply LEDs on the dc
power supply.
28
IBM System x3550 M3 Types 4254 and 7944: Installation and User's Guide
Error (!)
Description
Off
Normal operation
Off
No ac power to the
server or a problem
with the ac power
source.
On
No ac power to the
server or a problem
with the ac power
source and the
power-supply had
detected an internal
problem.
Off
Faulty
power-supply
On
Faulty
power-supply
Off
Power-supply not
fully seated, faulty
system board, or
faulty power-supply
On
Faulty
power-supply
On
Power-supply is
faulty but still
operational
Action
1. Check the ac power to the
server.
2. Make sure that the power
cord is connected to a
functioning power source.
3. Restart the server. If the error
remains, check the
power-supply LEDs.
4. Replace the power-supply.
v Make sure that the power cord
is connected to a functioning
power source.
v Replace the power supply.
Replace the power supply.
Replace the power supply.
1. Reseat the power supply.
2. If a power channel error LED
on the system board is not lit,
replace the power-supply
(see the documentation that
comes with the power supply
for instructions).
3. If a power channel error LED
on the system board is lit,
(trained service technician
only) replace the system
board.
Replace the power supply.
Replace the power supply.
Notes
This is a normal
condition when no ac
power is present.
This happens only
when a second power
supply is providing
power to the server.
Typically indicates a
power-supply is not
fully seated.