IBM System x3550 M3 Type 4254 Installation And User Manual page 35

1-u-high rack model server
Hide thumbs Also See for System x3550 M3 Type 4254:
Table of Contents

Advertisement

Table 2. Light path diagnostics panel LEDs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing", in the Problem Determination and Service Guide to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
LED
Description
OVER SPEC
The power supplies are using
(Continued)
more power than their maximum
rating.
Action
If the 12 V channel C error LED is lit, complete the following
steps:
1. Turn off the server and disconnect the power from the
server.
2. Remove the SAS/SATA RAID riser card, DIMMs in
connectors 1 through 9, and the microprocessor in socket
1.
Note: The server will not power-on when the
microprocessor in socket 1 or 2 is not installed in the
server. (Trained service technician only) Toggle the switch
block (SW4), bit 3 to allow the server to power-on. See
"System-board switches and jumpers" on page 39 for the
location of the SW4 switch block on the system board.
3. Restart the server to see whether the problem remains.
4. Reinstall each device that you removed in step 2 one at a
time, starting the server each time, to isolate the failing
device.
5. Replace any failing device.
6. (Trained service technician only) Replace the system
board.
If the 12 V channel D error LED is lit, complete the following
steps:
1. Turn off the server and disconnect the power from the
server.
2. (Trained service technician only) Remove the
microprocessor in socket 1.
Note: The server will not power-on when the
microprocessor in socket 1 or 2 is not installed in the
server. (Trained service technician only) Toggle the switch
block (SW4), bit 3 to allow the server to power-on. See
"System-board switches and jumpers" on page 39 for the
location of the SW4 switch block on the system board.
3. Restart the server to see whether the problem remains.
4. (Trained service technician only) Reinstall the
microprocessor in socket 1 and restart the server.
5. Replace any failing device.
6. (Trained service technician only) Replace the system
board.
(Continued on the next page.)
Chapter 1. The System x3550 M3 server
19