v The electromagnetic interference (EMI) integrity and cooling of the server are

Installing a hot-swap hard disk drive

To install a 2.5-inch hot-swap SAS or SATA hard disk drive, complete the following
steps.
Note: If you have only one hard disk drive, you must install it in the upper-left bay.
Drive-tray
assembly
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Remove the filler panel from the empty drive bay.
3. Touch the static-protective package that contains the drive to any unpainted
4. Install the hard disk drive in the drive bay:
5. If you are installing additional hot-swap hard disk drives, do so now.
If you have other devices to install or remove, do so now. Otherwise, go to
"Completing the installation" on page 103.

IDs for hot-swap hard disk drives

The hot-swap drive ID that is assigned to each drive is printed on the front of the
server. The following illustration shows the location of the IDs of the hard disk
drives. The ID numbers and the drive bay numbers are the same.
protected by having all bays and PCI and PCI Express slots covered or
occupied. When you install a drive, PCI, or PCI Express adapter, save the EMC
shield and filler panel from the bay or PCI adapter or PCI Express adapter slot
cover in the event that you later remove the device.
Drive handle
Filler panel
on page 44.
metal surface on the server; then, remove the drive from the package and place
it on a static-protective surface.
a. Make sure that the tray handle is in the open (unlocked) position.
b. Align the drive assembly with the guide rails in the bay.
c. Gently push the drive assembly into the bay until the drive stops.
d. Rotate the tray handle to the closed (locked) position.
e. Check the hard disk drive status LED to verify that the hard disk drive is
operating correctly. If the amber hard disk drive status LED for a drive is lit
continuously, that drive is faulty and must be replaced. If the green hard disk
drive activity LED is flashing, the drive is being accessed.
Note: If the server is configured for RAID operation using a ServeRAID
adapter, you might have to reconfigure your disk arrays after you
install hard disk drives. See the ServeRAID adapter documentation
for additional information about RAID operation and complete
instructions for using the ServeRAID adapter.
Chapter 2. Installing optional devices