8-2
Purpose
Adjustment/Operation test/check
Used to check and adjust the operation of the main
Function
charger grid voltage (high mode) in each copy mode
(Purpose)
and the control circuit.
Image process
Section
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Item
1
AE (145)
AE (145mm/s)
2
TEXT (145)
Character (145mm/s)
Character/Photo
3
TEXT/PHOTO (145)
(145mm/s)
4
PHOTO (145)
Photo (145mm/s)
5
TONER SAVE (145)
Toner save (145mm/s)
6
AE (122)
AE (122mm/s)
7
TEXT (122)
Character (122mm/s)
Character/Photo
8
TEXT/PHOTO (122)
(122mm/s)
9
PHOTO (122)
Photo (122mm/s)
10 TONER SAVE (122)
Toner save (122mm/s)
Min. unit: –25V increment
(
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
NO.
Set value
Grid High
1
4
–555V
2
6
–605V
3
6
–605V
4
6
–605V
5
2
–505V
6
3
–530V
7
5
–580V
8
5
–580V
9
5
–580V
10
2
–505V
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 10 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –555V (pattern 1), the
grid low voltage is –455V.
SIMULATION 8-2
Setting
Content
Default
range
4
6
6
6
2
1-12
3
5
5
5
2
Grid Low
–455V
–505V
–505V
–505V
–405V
–405V
–455V
–455V
–455V
–380V
AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 13
8-3
Purpose
Adjustment/Operation test/check
Used to check and adjust the operation of the main
Function
charger grid voltage (low mode) in each copy mode
(Purpose)
and the control circuit.
Image process
Section
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is highlighted.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Item
1
AE (145)
AE (145mm/s)
2
TEXT (145)
Character (145mm/s)
Character/Photo
3
TEXT/PHOTO (145)
(145mm/s)
4
PHOTO (145)
Photo (145mm/s)
5
TONER SAVE (145)
Toner save (145mm/s)
6
AE (122)
AE (122mm/s)
7
TEXT (122)
Character (122mm/s)
Character/Photo
8
TEXT/PHOTO (122)
(122mm/s)
9
PHOTO (122)
Photo (122mm/s)
10 TONER SAVE (122)
Toner save (122mm/s)
Min. unit: –25V increment
(
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
NO.
Set value
Grid High
1
4
–555V
2
6
–605V
3
6
–605V
4
6
–605V
5
2
–505V
6
3
–530V
7
5
–580V
8
5
–580V
9
5
–580V
10
2
–505V
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 10 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –555V (pattern 1), the
grid low voltage is –455V.
SIMULATION 8-3
Setting
Content
Default
range
4
6
6
6
2
1-12
3
5
5
5
2
Grid Low
–455V
–505V
–505V
–505V
–405V
–405V
–455V
–455V
–455V
–380V