Note: In SIM 7-1, pressing [CA] key terminates the simulation and the
machine enters the aging mode without resetting. Therefore, to
perform "4. Intermittent setup," the intermittent cycle must be set
with SIM 7-6 in advance.
Reset is not performed when the machine enters the aging mode.
7-6
Purpose
Setting/Operation test/check
Function (Purpose)
Used to set the cycle of intermittent aging.
Item
Operation
Operation/procedure
1. Enter the interval aging cycle time (sec) with the 10-key pad.
Refer to SIM 7-1.
2. Press the [START] key.
When the [START] key is pressed in aging, copying is performed con-
tinuously. This simulation is used to set the time interval between copy
operations in the unit of second.
This setting is valid when SIM 7-1 (Intermittent setting) is enabled.
Setting range
1-255
Default
3
7-8
Purpose
Setting/Operation test/check
Function
Used to set the display of the warm-up time.
(Purpose)
Item
Operation
Operation/procedure
1. Warm-up starts by the cover open/close.
(Can be performed repeatedly by open/close of the cover.)
2. The warm-up time is counted up and displayed in the unit of sec.
If the [CA] key is pressed at this time, count-up is interrupted to ter-
minate the simulation. (However, warm-up is continued.)
3. After completion of warming up, "WARM UP COMPLETED" is dis-
played and the control returns to the initial screen.
AR-M256/M257/M258/M316/M317/M318/5625/5631 SIMULATION 8 - 12
8
8-1
Purpose
Adjustment/Operation test/check
Used to check and adjust the operation of the
Function
developing bias voltage in each copy mode and the
(Purpose)
control circuit.
Image process
(Photoconductor/Developing/Transfer/Cleaning)
Section
Developer/Toner hopper
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value, and the display returns to the
original state.
Item
1
AE (145)
AE (145mm/s)
2
TEXT (145)
Character (145mm/s)
Character/Photo
3
TEXT/PHOTO (145)
(145mm/s)
4
PHOTO (145)
Photo (145mm/s)
5
TONER SAVE (145)
Toner save (145mm/s)
6
AE (122)
AE (122mm/s)
7
TEXT (122)
Character (122mm/s)
Character/Photo
8
TEXT/PHOTO (122)
(122mm/s)
9
PHOTO (122)
Photo (122mm/s)
10
TONER SAVE (122)
Toner save (122mm/s)
(
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
The minimum increment is 5V.
The result of (Set value) / 5 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *5)
is used as the set value.
Therefore, a multiple number of 5 must be entered. If not, the value +1
to +4 is displayed after pressing [START] key.
SIMULATION 8-1
SIMULATION 8-1
DV BIAS COPY SETTING. INPUT VALUE 200-550, AND PRESS
START.
1: AE
426
2: TEXT
450
3: TEXT/PHOTO
450
4: PHOTO
450
5: SUPER/PHOTO
400
6: TONER SAVE
376
Setting
Content
Default
range
450
500
500
500
400
200-
650
400
450
450
450
376
426
1/1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m258Ar-m257Ar-m318Ar-5625Ar-5631Ar-m316 ... Show all

Table of Contents