Sharp AR-M256 Service Manual page 102

Digital multifunctional system
Hide thumbs Also See for AR-M256:
Table of Contents

Advertisement

Trouble
code
Main
Sub
code
code
E1
80
Content
IMC PWB communication trouble
(protocol)
Details
Communication trouble between MCU and
IMC PWB (Protocol error)
Cause
IMC PWB connector disconnection.
Motherboard connector pin breakage.
IMC PWB ROM defect, data failure.
Check
Check the connectors of the IMC PWB and
and
MCU PWB.
remedy
Check the grounding of the copier.
Check the ROM of the IMC PWB.
81
Content
IMC PWB communication trouble (Parity)
Details
Communication trouble between MCU and
printer IMC (Parity error)
Cause
IMC PWB connector disconnection.
Motherboard connector pin breakage.
IMC PWB ROM defect, data failure.
Check
Check the connectors of the IMC PWB and
and
MCU PWB.
remedy
Check the grounding of the copier.
Check the ROM of the IMC PWB.
82
Content
IMC PWB communication trouble
(Overrun)
Details
Communication trouble between MCU and
IMC PWB (Overrun error)
Cause
IMC PWB connector disconnection.
Motherboard connector pin breakage.
IMC PWB ROM defect, data failure.
Check
Check the connectors of the IMC PWB and
and
MCU PWB.
remedy
Check the grounding of the copier.
Check the ROM of the IMC PWB.
84
Content
IMC PWB communication trouble
(Framing)
Details
Communication trouble between MCU and
IMC PWB (Framing error)
Cause
IMC PWB connector disconnection.
Motherboard connector pin breakage.
IMC PWB ROM defect, data failure.
Check
Check the connectors of the IMC PWB and
and
MCU PWB.
remedy
Check the grounding of the copier.
Check the ROM of the IMC PWB.
88
Content
IMC PWB communication trouble
(Time-out)
Details
Communication trouble between MCU and
IMC PWB (Time-out error)
Cause
IMC PWB connector disconnection.
Motherboard connector pin breakage.
IMC PWB ROM defect, data failure.
Check
Check the connectors of the IMC PWB and
and
MCU PWB.
remedy
Check the grounding of the copier.
Check the ROM of the IMC PWB.
Details of trouble
AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 3
Trouble
code
Main
Sub
code
code
E7
02
Content
LSU trouble
Details
BD signal from LSU is not detected in a
constant cycle (Kept OFF or ON)
Cause
LSU connector or LSU inside harness
trouble or disconnection.
Polygon motor rotation abnormality.
Laser does not illuminate.
MCU PWB failure.
Check
Check for disconnection of the LSU
and
connector.
remedy
Check the LSU operation with SIM 61-1.
Check that the polygon motor rotates
normally.
Check laser LED lighting.
Replace the LSU unit.
Replace the MCU PWB.
10
Content
CCD black level error
Details
CCD black reference plate scan level
abnormality when the copy lamp turns off.
Cause
Flat cable installation failure to CCD unit.
CCD unit error.
Check
Check flat cable installation to the CCD
and
unit.
remedy
Check CCD unit.
11
Content
CCD white level error
Details
Improper CCD white reference plate
reading level for copy lamp lighting
Cause
Flat cable installation failure to CCD unit.
Dirt on the mirror, lens, and reference
white plate.
Copy lamp lighting trouble.
CCD unit abnormality.
MCU PWB abnormality. (Occurred in the
RSPF scan position)
Check
Clean the mirror, the lens, and the
and
reference white plate.
remedy
Check the copy lamp light quantity and its
operation. (SIM 5-3)
Check CCD unit.
Check MCU PWB.
12
Content
Shading trouble
Details
White correction is not completed in the
specified number of times.
Cause
Flat cable installation failure to CCD unit.
Dirt on the mirror, lens, and reference.
white plate.
Copy lamp lighting trouble.
CCD unit abnormality.
MCU PWB abnormality.
Check
Clean the mirror, the lens, and the
and
reference white plate.
remedy
Check the copy lamp light quantity and its
operation. (SIM 5-3)
Check CCD unit.
Check MCU PWB.