3.9

Scanner Unit

(1)
(2)
Scanner Unit
(3)
(4)
Note:
Download Free Service Manual and Resetter Printer at http://printer1.blogspot.com
Remove the three screws.
Lift out the scanner unit.
Screw
Main Cover
Disconnect the three connectors from the driver PCB.
Remove the screw and the tape, and lift the toner sensor PCB from the scanner
unit.
Never touch the inside of the scanner unit or the mirror when disassembling or
reassembling. If there is any dirt or dust on the mirror, blow it off.