Scanner Unit; Main Pcb Assy - Brother HL-730Plus Service Manual

Hide thumbs Also See for HL-730Plus:
Table of Contents

Advertisement

3.5

Scanner Unit

(1) Remove the three screws.
(2) Lift out the scanner unit.
(3) Disconnect the three connectors of the scanner unit from the panel sensor PCB.
(4) Remove the screw and disassemble the Toner sensor PCB from the Scanner unit.
   1/
4  
NOTE: Never touch the inside of the scanner unit or the mirror when disassembling or
reassembling. If there is any garbage or dust on the mirror, blow it off.
3.6

Main PCB Assy

(1) Remove three screws securing the main PCB holder on the back side of the printer.
(2) Grasp the hooks at left and right and draw out the main PCB assy.
 1/ 
. 

4 

 
Fig. 3.6
#8 4 
. 
Fig. 3.7
    '132 1,2 1(*
1   1/