Note:
(7)
(8)
Download Free Service Manual and Resetter Printer at http://printer1.blogspot.com
Follow instructions below when installing the thermistor in the fixing unit.
• Place the cleaner felt of the cleaner ASSY under the heat roller.
• Place the end of the thermistor on the heat roller.
• Insert the boss1 of the thermistor into the hole of the fixing unit frame.
• Do not place the thermistor on the boss2 of the fixing unit frame.
Boss2
Boss1
Cleaner ASSY
Remove the two screws.
Open the fixing unit cover along the open side of the fixing unit cover.
Screws
Fixing unit
v r
Pressure Roller
Thermistor
Fig. 3.17
Fixing unit frame
Fig. 3.18
III-11
Heat roller
Fixing unit frame
Fixing unit cover
Shaft