Soft Adjustments
6.3
Soft Adjustments
6.3.1
Setting of Head
Temperature
(Reference value)
(T2170/T2280 only)
6-12
Necessary tools:
Thermometer
Caution:
Make sure the printhead has room temperature.
–
Make sure the printhead has room temperature
–
Keep Top Cover Closed
–
Press keys ONLINE and SETUP simulaneously while Power On until
TESTMODE is displayed shortly
–
Press key "Temp. cal."
Print
Temp.cal
Back
Next
1
2
3
–
Set the actual head temperature (= room temperature) in a range between 15°C
and 30°C using the keys "<" and ">"
Temp.cal=23
Set
<
>
Exit
1
2
3
–
Confirm your setting by pressing SET key. The new value is marked with a star
(*). (Leaving the item with key EXIT the value will not be stored)
–
Leave TESTMODE by pressing ONLINE key
Recommendation:
You may use normal thermometer with a tolerance of 2 degrees max. Under normal
working conditions you do not need to adjust a yet installed printhead.
Attention:
Do not install/adjust a "hot" printhead.
Remark:
°
0 °C equals 32
F
°
°
t
=0.55 * (
F-32)
C
C
Online
4
Setup
*
Online
4
Setup
°
°
t
=(1.8 *
C+32)
F
F
Adjustments
Example:
21 °C
0.55 (70 °F - 23)
70 °F
(1.8 20°C + 32)