Soft Adjustments; Setting Of Head Temperature (Reference Value) (T2170/T2280 Only) - Tally T2265 SprintPro Maintenance Manual

Hide thumbs Also See for T2265 SprintPro:
Table of Contents

Advertisement

Soft Adjustments

6.3
Soft Adjustments
6.3.1
Setting of Head
Temperature
(Reference value)
(T2170/T2280 only)
6-12
Necessary tools:
Thermometer
Caution:
Make sure the printhead has room temperature.
Make sure the printhead has room temperature
Keep Top Cover Closed
Press keys ONLINE and SETUP simulaneously while Power On until
TESTMODE is displayed shortly
Press key "Temp. cal."
Print
Temp.cal
Back
Next
1
2
3
Set the actual head temperature (= room temperature) in a range between 15°C
and 30°C using the keys "<" and ">"
Temp.cal=23
Set
<
>
Exit
1
2
3
Confirm your setting by pressing SET key. The new value is marked with a star
(*). (Leaving the item with key EXIT the value will not be stored)
Leave TESTMODE by pressing ONLINE key
Recommendation:
You may use normal thermometer with a tolerance of 2 degrees max. Under normal
working conditions you do not need to adjust a yet installed printhead.
Attention:
Do not install/adjust a "hot" printhead.
Remark:
°
0 °C equals 32
F
°
°
t
=0.55 * (
F-32)
C
C
Online
4
Setup
*
Online
4
Setup
°
°
t
=(1.8 *
C+32)
F
F
Adjustments
Example:
21 °C
0.55 (70 °F - 23)
70 °F
(1.8 20°C + 32)

Hide quick links: