Tandberg Data StorageLibrary T40+ Series Installation And User Manual page 89

Professional tape backup and data protection solution
Table of Contents

Advertisement

RAS
Severity
Ticket
Level
R0206
High
R0207
High
R0208
High
R0210
High
R0211
High
R1001
Urgent
R1100-
Urgent
R1128
StorageLibrary T40+ Series Installation and User Guide
Display Message
Description
Drive-n cleaning
The cleaning
failed. Expired
operation failed
cleaning tape.
due to an expired
cleaning tape.
Cleaning cartridge
An cleaning
in drive-n. Can not
cartridge has
be moved home.
been found in
one of the drives
witch can not be
moved home.
Drive-n cleaning
The cleaning
failed. Invalid
operation failed
cleaning tape.
due to an invalid
cleaning tape.
Power loss
Power loss
detected on power
detected on
source #1.
power source #1.
Power loss
Power loss
detected on power
detected on
source #2
power source #2.
Failed moving the
The robotics was
robotics.
not able to move.
Failed to stow at
The robotics is
slot n.
not able to stow
the cartridge to
the magazine
Suggested Action
Please remove the expired
cleaning media from the system,
and import a new cleaning media.
To import cleaning media, you
should open the I/E station and
insert one or more cleaning tapes.
The cartridges must be assign to
the Cleaning or System partition.
All I/E and cleaning slots are
occupied.
Please remove a tape from the
I/E station, or from the cleaning
slots, or use the Unload Drive
command to move the cleaning
cartridge from the drive.
When a cartridge has been
removed, please reboot the
loader and retry the operation.
Please remove the invalid
cleaning media from the system,
and import a new cleaning media.
To import cleaning media, you
should open the I/E station and
insert one or more cleaning tapes.
The cartridges must be assign to
the Cleaning or System partition.
Power loss detected on power
source #1.
This failure can be caused by an
AC power loss, the power supply
being turned off, the power cable
not being inserted properly, or a
Power CRU hardware failure.
Power loss detected on power
source #2.
This failure can be caused by an
AC power loss, the power supply
being turned off, the power cable
not being inserted properly, or a
Power CRU hardware failure.
Reboot the loader and retry the
operation.
Reboot the loader and retry the
operation.
Remove the magazine if possible.
Remove all cartridges.
Verify that the cartridge is not
damaged.
Insert empty magazines.
Power cycle the loader.
Retry the operation.
Retry the operation with a new
magazine.
89