RAS
Severity
Ticket
Level
R1129-
Urgent
R112C
R1200-
Urgent
R1228
R1229-
Urgent
R122C
R2000
Urgent
R2001
Urgent
R2002
Low
R2003
Urgent
R3000
Urgent
R3001
Urgent
90
Display Message
Description
Failed to stow at
Failed to insert
drive n.
cartridge in drive
Failed to fetch at
The robotics is
slot n.
not able to fetch
the requested
cartridge from the
magazine
Failed to fetch at
Failed to fetch
drive n.
cartridge in drive
No drive detected
The library is not
able to detect the
drive.
Drive hardware
The library has
fault is detected
detected a drive
hardware fault.
Drive firmware
A firmware
update available
update is
available for the
tape drive
Drive firmware
A firmware
update
update is
recommended
recomended for
the tape drive.
The Pass-Thru
The library was
system is not
not able to move
correctly installed.
the Pass-Thru
box between the
systems.
The Pass-Thru
The Pass-Thru
magazine is not in
magazine is not
place
in place.
Suggested Action
Reboot the loader and retry the
operation.
If failure persists, insert the
cartridge into a magazine slot,
remove the magazine and verify
that the cartridge is not damaged.
If failure persists, replace the
drive CRU.
Reboot the loader and retry the
operation.
Remove the magazine if possible.
Remove all cartridges.
Verify that the cartridge is not
damaged.
Insert empty magazines.
Power cycle the loader.
Retry the operation.
Retry the operation with a new
magazine
Reboot the loader and retry the
operation.
If failure persists, replace the
drive CRU.
Please verify that the drive CRU
is installed.
Reboot the loader and retry the
operation. If the problem persists
please contact technical support.
Please verify that the drive CRU
is installed. Reboot the loader
and retry the operation. If failure
persists, replace the drive CRU.
Update the drive firmware to the
latest version available from
http://www.tandbergdata.com.
Update the drive firmware to the
latest version available from
http://www.tandbergdata.com.
Please verify that the blind plate
has been removed, and that the
systems are correctly installed
into the rack.
Please insert the Pass-Thru
magazine and retry the operation.
Shipping or Transporting the StorageLibrary